Virtual fencing (VF) represents a way to simplify traditional pasture management with its high labour and cost requirements for fencing and to make better use of the 'beneficial' agronomic and ecological effects of livestock grazing. In this study, the VF technology (® Nofence, AS, Batnfjordsøra Norway) was used with Fleckvieh heifers to investigate possible welfare impacts on the animals compared to conventionally fenced animals when they were trained to respond correctly to the system. The Nofence® collars (attached to the neck of the heifers) send acoustic signals as a warning when the animals approach the VF line, which was set up by GPS coordinates within the Nofence®-App, followed by an electric pulse when they do not stop or return. The heifers had no experience with VF prior to the study. Two treatments (VF versus physical fencing (PF)) were applied to six groups of four heifers each (three groups per treatment) over three 12-day time replicates. One VF line separated the pasture of the VF group into an accessible or non-accessible area. The control group had a PF line. Both groups were equipped with Nofence® collars (deactivated for the PF group). The trial took place on two adjacent paddocks of 1 000 m each following a 12-day schedule which was divided into three sections: visual support of the VF line by a physical barrier (first 2 days), only virtual border without visual support, moving the VF line (on day 8). Each time replicate followed the next successively on different paddocks with two new groups of heifers, which were grazed 5 h daily. During the whole experiment, the behaviour of each of the four animals per group was continuously observed; 2 h a.m., 2 h p.m. Exclusion by the VF line was effective in our trial. None of the heifers crossed the virtual boundary, i.e. the time spent in exclusion zone was zero. The heifers received 2.70 ± 2.63 acoustic signals and 0.30 ± 0.36 electric pulses (mean ± SD) per heifer and hour during all time replicates. Main cattle behaviour on pasture was not affected by the fencing system. Live weight gain, herbage consumption and faecal cortisol metabolites also revealed no significant differences. The duration until the heifers restarted grazing after an electric pulse from the Nofence® collar was significantly shorter than after an electric pulse from the physical fence. We can summarise that in our study, cattle well-being on pasture was not negatively affected by VF compared to PF.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.animal.2022.100614 | DOI Listing |
World J Cardiol
January 2025
Department of Internal Medicine-II, Paracelsus Medical University Salzburg, Salzburg 5020, Austria.
The recurrence of atrial fibrillation (AF) in patients after successful radiofrequency catheter ablation (RFCA) appears to be an unresolved clinical issue and needs to be clearly elucidated. There are many factors associated with AF recurrence, such as duration of AF, male sex, concomitant heart failure, hemodynamic parameters, chronic obstructive pulmonary disease, hypertension, obstructive sleep apnea, hyperthyroidism, smoking and obesity. However, the inflammatory changes are strongly associated with electrical and structural cardiac remodeling, cardiac damage, myocardial fibrotic changes, microvascular dysfunction and altered reparative response.
View Article and Find Full Text PDFNMR Biomed
March 2025
Centre for Advanced Imaging, The University of Queensland, St Lucia, Queensland, Australia.
In this work, we introduce spatial and chemical saturation options for artefact reduction in magnetic resonance fingerprinting (MRF) and assess their impact on T and T mapping accuracy. An existing radial MRF pulse sequence was modified to enable spatial and chemical saturation. Phantom experiments were performed to demonstrate flow artefact reduction and evaluate the accuracy of the T and T maps.
View Article and Find Full Text PDFVitam Horm
January 2025
Department of Physiology, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran. Electronic address:
Opioid use disorder (OUD) is considered a global health issue that affects various aspects of patients' lives and poses a considerable burden on society. Due to the high prevalence of remissions and relapses, novel therapeutic approaches are required to manage OUD. Deep brain stimulation (DBS) is one of the most promising clinical breakthroughs in translational neuroscience.
View Article and Find Full Text PDFHeart Rhythm
January 2025
Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium.
Background: Catheter ablation is an effective treatment for atrial fibrillation (AF). Pulsed field ablation (PFA) has emerged as a novel energy modality, which relies on high-voltage electric fields to achieve cardiac tissue ablation. Data on its efficacy in the elderly are scarce.
View Article and Find Full Text PDFComput Biol Med
January 2025
Department of Electrical and Electronics Engineering, Sri Sivasubramaniya Nadar College of Engineering, Chennai, India. Electronic address:
Cardiovascular disease (CVD) is caused by the abnormal functioning of the heart which results in a high mortality rate across the globe. The accurate and early prediction of various CVDs from the electrocardiogram (ECG) is vital for the prevention of deaths caused by CVD. Artificial intelligence (AI) is used to categorize and accurately predict various CVDs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!