To compare the safety and efficacy of manual compression versus use of the MANTA closure device for access management after Impella removal on the intensive care unit (ICU). The number of patients treated with percutaneous left ventricular assist devices (pLVAD), namely Impella and ECMO, for complex cardiac procedures or shock, is growing. However, removal of pLVAD and large bore arteriotomy closure among such patients on the ICU remains challenging, since it is associated with a high risk for bleeding and vascular complications. Patients included in a prospective registry between 2017 and 2020 were analyzed. Bleeding and vascular access site complications were assessed and adjudicated according to VARC-2 criteria. We analyzed a cohort of 87 consecutive patients, who underwent access closure after Impella removal on ICU by using either the MANTA device or manual compression. The cohort´s mean age was 66.1 ± 10.7 years and 76 patients (87%) were recovering from CS. Mean support time was 40 h (interquartile range 24-69 h). MANTA was used in 31 patients (35.6%) and manual compression was applied in 56 patients (64.4%). Overall access related bleedings were significantly lower in the MANTA group (6.5% versus 39.3% (odds ratio (OR) 0.10, 95% CI 0.01-0.50; p = 0.001), and there was no significant difference in vascular complications between the two groups (p = 0.55). Our data suggests that the application of the MANTA device directly on the ICU is safe. In addition, it seems to reduce access related bleeding without increasing the risk of vascular complications.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9388691 | PMC |
http://dx.doi.org/10.1038/s41598-022-18184-x | DOI Listing |
BMC Cardiovasc Disord
January 2025
Heart Center, Women and Children's Hospital, Qingdao University, 6 Tongfu Road, Qingdao, 266034, Shandong, China.
Objectives: To evaluate the efficacy and safety of purse-string sutures (PSS) compared with manual compression for access hemostasis in children with atrial septal defects (ASDs) after large-caliber venous delivery sheaths removal.
Methods: We conducted a retrospective clinical data review of 271 children with ASDs who underwent transcatheter device closure through large-caliber venous delivery sheaths (≥ 8 Fr) at our institution from January 2018 to January 2023. The PSS group (n = 144) was compared to the control group (n = 127), which underwent manual compression for femoral venous hemostasis after sheath removal, focusing on hemostatic time, limb braking time, bed rest time, hospital stay, and vascular access complications.
J Vasc Access
January 2025
Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung, Taiwan.
Background: Extracorporeal membrane oxygenation (ECMO) is a critical treatment for severe cardiopulmonary failure. However, traditional ECMO decannulation methods, such as manual compression and surgical repair, are associated with significant complications. This study evaluates suture-mediated closure devices, specifically Perclose ProGlide, as a potentially favorable decannulation strategy.
View Article and Find Full Text PDFDiagnostics (Basel)
January 2025
Faculty of Applied Science, Uplands College of Science and Technology Incorporated (UCSI), No. 1, Jalan Menara Gading, Kuala Lumpur 56000, Malaysia.
: This study compares system-reported organ doses (ODs) to manually calculated mean glandular doses (MGDs) in mammography across multiple centers and manufacturers in Dubai. : A retrospective study of 2754 anonymized mammograms from six clinics in Dubai were randomly retrieved from a central dose survey database. Organ doses were documented along with other dosimetry information like kVp, mAs, filter, target, compression force, and breast thickness.
View Article and Find Full Text PDFJ Contemp Dent Pract
September 2024
Department of Prosthodontics, Bharati Vidyapeeth (Deemed to be University) Dental College and Hospital, Sangli, Maharashtra, India, ORCID: https://orcid.org/0000-0002-6661-0931.
Aim: The aim of this systematic review was to evaluate the effect of build orientation on the mechanical and physical properties of additively manufactured resin using digital light processing (DLP).
Background: The properties of 3D-printed materials are influenced by various factors, including the type of additive manufacturing (AM) system and build orientation. There is a scarcity of literature on the effect of build orientation on the mechanical and physical properties of additively manufactured resins using DLP technology in dentistry.
Ann Thorac Surg Short Rep
December 2024
Division of Cardiac Surgery, Inova Heart and Vascular Institute, Inova Health Systems, Falls Church, Virginia.
Background: DeBakey type I aortic dissections (AD) are most frequently treated with hemiarch repair. A subset of patients demonstrates persistent distal end-organ ischemia secondary to persistent true lumen (TL) compression. We describe the use of bare metal stent grafting across the residual arch dissection with the Zenith Dissection Endovascular Stent (ZDES, Cook Medical) in 7 patients with type I AD that was repaired in a hemiarch configuration with a compromised distal TL and organ malperfusion.