[Three-dimensional finite element analysis of exo-cortical placement of humeral calcar screw for reconstruction of medial column stability].

Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi

Department of Orthopaedic Surgery, Yangpu Hospital, Tongji University, Shanghai, 200090, P. R. China.

Published: August 2022

Objective: To explore the biomechanical stability of the medial column reconstructed with the exo-cortical placement of humeral calcar screw by three-dimensional finite element analysis.

Methods: A 70-year-old female volunteer was selected for CT scan of the proximal humerus, and a wedge osteotomy was performed 5 mm medially inferior to the humeral head to form a three-dimensional finite element model of a 5 mm defect in the medial cortex. Then, the proximal humeral locking plate (PHILOS) was placed. According to distribution of 2 calcar screws, the study were divided into 3 groups: group A, in which 2 calcar screws were inserted into the lower quadrant of the humeral head in the normal direction for supporting the humeral head; group B, in which 1 calcar screw was inserted outside the cortex below the humeral head, and the other was inserted into the humeral head in the normal direction; group C, in which 2 calcar screws were inserted outside the cortex below the humeral head. The models were loaded with axial, shear, and rotational loadings, and the biomechanical stability of the 3 groups was compared by evaluating the peak von mises stress (PVMS) of the proximal humerus and the internal fixator, proximal humeral displacement, neck-shaft angle changes, and the rotational stability of the proximal humerus. Seven cases of proximal humeral fractures with comminuted medial cortex were retrospectively analyzed between January 2017 and December 2020. Locking proximal humeral plate surgery was performed, and one (5 cases) or two (2 cases) calcar screws were inserted into the inferior cortex of the humeral head during the operation, and the effectiveness was observed.

Results: Under axial and shear force, the PVMS of the proximal humerus in group B and group C was greater than that in group A, the PVMS of the internal fixator in group B and group C was less than that in group A, while the PVMS of the proximal humerus and internal fixator between group B and group C were similar. The displacement of the proximal humerus and the neck-shaft angle change among the 3 groups were similar under axial and shear force, respectively. Under the rotational torque, compared with group A, the rotation angle of humerus in group B and group C increased slightly, and the rotation stability decreased slightly. All the 7 patients were followed up 6-12 months. All the fractures healed, and the healing time was 8-14 weeks, with an average of 10.9 weeks; the neck-shaft angle changes (the difference between the last follow-up and the immediate postoperative neck-shaft angle) was (1.30±0.42)°, and the Constant score of shoulder joint function was 87.4±4.2; there was no complication such as humeral head varus collapse and screw penetrating the articular surface.

Conclusion: For proximal humeral fractures with comminuted medial cortex, exo-cortical placement of 1 or 2 humeral calcar screw of the locking plate outside the inferior cortex of the humeral head can also effectively reconstruct medial column stability, providing an alternative approach for clinical practice.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9379462PMC
http://dx.doi.org/10.7507/1002-1892.202202032DOI Listing

Publication Analysis

Top Keywords

humeral head
36
proximal humerus
24
proximal humeral
20
group group
20
humeral
17
calcar screw
16
calcar screws
16
cortex humeral
16
neck-shaft angle
16
group
14

Similar Publications

The Transverse Humeral Ligament: An Anatomical Narrative Review.

Clin Anat

December 2024

Division of Gross and Clinical Anatomy, Department of Anatomy, Kurume University School of Medicine, Fukuoka, Japan.

Shoulder pain often involves the tendon of the long head of the biceps brachii (LHBT) and the transverse humeral ligament (THL). Traditionally, the THL is considered a ligament that prevents the LHBT from dislocating, but recent studies suggest that it may be part of the subscapularis tendon. This review evaluates the nature of the THL and its overlying structures.

View Article and Find Full Text PDF

Background: Patients undergoing reverse shoulder arthroplasty (RSA) for rotator cuff arthropathy may present with an external rotation (ER) lag due to posterior rotator cuff insufficiency. As a result, the addition of a latissimus dorsi (LD) tendon transfer in combination with RSA has become increasingly utilized. Initial descriptions of LD tendon transfer involved rerouting of the LD tendon posterior to the long head of the triceps tendon.

View Article and Find Full Text PDF

Anterior shoulder instability with glenoid bone lesion can be treated with the Eden-Hybinette procedure utilizing a tricortical iliac crest bone graft or the Latarjet procedure. This study aimed to evaluate the glenohumeral joint (GHJ) kinematics throughout an external shoulder rotation following the Eden-Hybinette and Latarjet procedures. Nine human specimens were examined with dynamic radiostereometry during a GHJ external rotation with anteriorly directed loads from 0 to 30 N.

View Article and Find Full Text PDF

Objective: To explore changes of humerus torque screw tip distance on stability of proximal humeral internal locking system (PHILOS) by finite element analysis, in order to provide reference for selection of intraoperative plant size.

Methods: The proximal humerus 3D model was constructed based on Synbone artificial bone model in 3D engineering drawing software, and the corresponding 3D model was constructed based on PHILOS bone plate contour. The model was modified to simulate comminuted proximal humerus fracture, and the operation model was simulated after fracture, and the fixed operation model was assembled, the apex distance of humerus moment screw was set as 4, 8, 12 and 16 mm respectively.

View Article and Find Full Text PDF

Background: There is a relative paucity of studies examining how the superior capsule reconstruction (SCR) may alter the kinematics of the glenohumeral joint capsule itself, specifically with respect to rotation and translation in the anterior-posterior and superior-inferior planes. This then raises the possibility that the SCR may be having unintended consequences on glenohumeral kinematics. The purpose of this study was to quantify the glenohumeral joint kinematics following Fascia Lata SCR (FL-SCR).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!