Time-of-flight (TOF) and resolution modeling (RM) algorithms are frequently used in clinical PET images, and inclusion of these corrections should measurably improve image quality. We quantified the effects of these correction algorithms on reconstructed images via the following metrics: recovery coefficients (RCs), contrast-to-noise ratio (CNR), noise-power spectrum (NPS), modulation transfer function (MTF), and the full width at half maximum (FWHM) of a point source. The goal of this experiment was to assess the effects of the correction algorithms when applied singly or together. Two different phantom tests were performed and analyzed by custom software. FWHM and MTF were measured using capillary tube point sources, while RCs, CNR, and NPS were measured using an image quality body phantom. Images were reconstructed with both TOF and RM, only TOF, only RM, or neither correction. The remaining reconstruction parameters used the standard clinical protocol. RM improved RCs, FWHM, and MTF, without increasing overall noise significantly. TOF improves CNR for small objects FWHM or MTF but did not decrease noise. RCs were not statistically improved by enabling these algorithms. Inclusion of both correction algorithms in image reconstruction provides an overall improvement to all metrics relative to the uncorrected image, but not by a significant margin in multiple aspects.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9588277PMC
http://dx.doi.org/10.1002/acm2.13751DOI Listing

Publication Analysis

Top Keywords

image quality
12
correction algorithms
12
fwhm mtf
12
resolution modeling
8
effects correction
8
image
5
algorithms
5
characterization time
4
time flight
4
flight resolution
4

Similar Publications

Background: Bulbar function is frequently impaired in patients with spinal muscular atrophy (SMA). Although extremely important for the patient's quality of life, it is difficult to address therapeutically. Due to bulbar dysfunction, maximum mouth opening (MMO) is suspected to be reduced in children with SMA.

View Article and Find Full Text PDF

Developing an automatic treatment record review system for quality assurance of patient treatment delivery in radiation therapy.

Radiat Oncol

January 2025

Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China.

Background And Purpose: Treatment record contains most of information related to treatment plan delivery in radiation therapy. Reviewing treatment record is an important quality assurance (QA) task for safety and quality of patient treatments. This task is usually performed by senior medical physicists.

View Article and Find Full Text PDF

Introduction: In 2020, 368 million people globally were affected by knee osteoarthritis, and prevalence is projected to increase with 74% by 2050. Relatively high rates of dissatisfactory results after total knee arthroplasty (TKA), as reported by approximately 20% of patients, may be caused by sub-optimal knee alignment and balancing. While mechanical alignment has traditionally been the goal, patient-specific alignment strategies are gaining interest.

View Article and Find Full Text PDF

Background: The quality of life for low vision patients is a comprehensive concept that involves multiple aspects, including physical, psychological, and social aspects. Visual impairment is an important factor in the decline of patients' quality of life. The purpose of this study is to investigate the impact and feasibility of carrying out low vision rehabilitation nursing on the quality of life and nursing burden of low vision patients.

View Article and Find Full Text PDF

The facial gestalt (overall facial morphology) is a characteristic clinical feature in many genetic disorders that is often essential for suspecting and establishing a specific diagnosis. Therefore, publishing images of individuals affected by pathogenic variants in disease-associated genes has been an important part of scientific communication. Furthermore, medical imaging data is also crucial for teaching and training deep-learning models such as GestaltMatcher.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!