Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Nursing is a high musculoskeletal disorder (MSD) risk job with high workload demands. This study combines Digital Human Modelling (DHM) and Discrete Event Simulation (DES) to address the need for tools to better manage MSD risk. This novel approach quantifies physical-workload, work-performance, and quality-of-care, in response to varying geographical patient-bed assignments, patient-acuity levels, and nurse-patient ratios. Lumbar loads for 86 care-delivery tasks in an acute care hospital unit were used as inputs in a DES model of the care-delivery process, creating a shift-long time trace of the biomechanical load. Peak L4/L5 compression and moment were 3574 N and 111.58 Nm, respectively. This study reports trade-offs in all three experiments: (i) increasing geographical patient-bed assignment distance decreased L4/L5 compression (8.8%); (ii) increased patient-acuity decreased L4/L5 moment (4%); (iii) Increased nurse-patient ratio decreased L4/L5 compression (10%) and moment (17%). However, in all experiments, Quality of care indicators deteriorated (20, 19, and 29%, respectively). This research has the potential to support decision-makers by developing a simulation tool that quantifies the impact of varying operational and design-policies in terms of biomechanical-load and quality of care. The demonstrator-model reports: as geographical patient-bed distance, patient-acuity levels, and nurse-patient ratios increase, biomechanical-load reduces, and quality of care deteriorates.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/00140139.2022.2113921 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!