At present, there are few clinical studies on the application of high-concentration sodium chloride solutions in intracavitary ECG-guided catheter tip localization during the arm infusion port implantation. This study observed the effects of sodium chloride solutions with different concentrations on intracavitary ECG-guided arm infusion port implantation in the patients with cancer. The 657 patients receiving arm infusion port implantation in our hospital between January 2020 and August 2021 were randomly divided into 0.9% sodium chloride solution conduction group (group A), 5.45% sodium chloride solution conduction group (group B) and 10% sodium chloride solution conduction group (group C). The derived rate of stable intracavitary ECG, the occurrence rate of characteristic P wave, the time used for catheter tip localization and the optimal position rate of catheter tip were compared between the three groups. The derived rate of stable intracavitary ECG was significantly higher in the group B (97.78%) and group C (98.63%) than in the group A (93.90%) (all P < 0.05). The occurrence rate of characteristic P wave was also significantly higher in the group B (96.89%) and group C (97.72%) than in the group A (88.73%) (all P < 0.001). The time used for catheter tip localization was significantly shorter in the group B [(49.73 ± 8.15) s] and group C [(48.27 ± 8.61) s] than in the group A [(69.37 ± 19.99) s] (all P < 0.001). There was no significant difference in the optimal position rate of catheter tip among the three groups (P > 0.05). The 5.45% and 10% sodium chloride solutions are significantly superior comparing with 0.9% sodium chloride solution in the derived rate of stable intracavitary ECG, occurrence rate of characteristic P wave and time used for catheter tip localization, but there were no significant differences between 5.45 and 10% sodium chloride solutions. Moreover, the 5.45% sodium chloride solution is closer to physiological state comparing with 10% sodium chloride solution, so the 5.45% sodium chloride solution may be recommended for the intracavitary ECG-guided arm infusion port implantation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9378698PMC
http://dx.doi.org/10.1038/s41598-022-15156-zDOI Listing

Publication Analysis

Top Keywords

sodium chloride
24
chloride solution
16
arm infusion
16
infusion port
16
port implantation
16
intracavitary ecg
12
solution conduction
12
conduction group
12
group group
12
group
9

Similar Publications

Background: Low-volume hypertonic solutions, such as half-molar lactate (LAC), may be a potential treatment used for fluid resuscitation. This study aimed to evaluate the underlying cardiovascular effects and mechanisms of LAC infusion compared to sodium-matched hypertonic sodium chloride (SAL).

Methods: Eight healthy male participants were randomized in a controlled, single-blinded, crossover study.

View Article and Find Full Text PDF

This study aims to synthesize a new localized drug delivery system of bioglass, polyvinyl alcohol (PVA), cellulose (CNC), and sodium alginate (SA) beads as a carrier for methotrexate (MTX) drugs for the treatment of osteosarcoma. Methotrexate /Bioglass-loaded Polyvinyl/Cellulose/Sodium alginate biocomposite beads were prepared via the dropwise method with different concentrations of (65%SiO-30%CaO- 5%PO) bioglass. Samples were named B0, S0, S1, S2, and S3, respectively.

View Article and Find Full Text PDF

Threshold determination forms an integral part of sensory and consumer studies applied for product control and development. The authors examined the potential of an impedimetric electronic tongue to discriminate basic tastes and consider limitations pertaining to the sensory evaluation process. Three samples at lower, medium, and higher concentration levels of basic taste compounds were prepared and subjected to consumer studies (n = 60) using the difference from-control (DFC) test.

View Article and Find Full Text PDF

Feasibility of very low iodine dose aortoiliac CT angiography using dual-source photon-counting detector CT.

Eur J Radiol

January 2025

Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:

Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.

Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.

View Article and Find Full Text PDF

Background Heart failure (HF) is commonly managed by addressing water and sodium (Na) balance, with arterial circulation playing a major role in influencing renal Na and water excretion. Recently, chloride (Cl) has been recognized as an important factor in HF, associated with volume regulation and its modulation of renin-angiotensin-aldosterone system (RAAS) activity through macula densa signaling, which impacts Na retention and neurohormonal activation. Acetazolamide, a carbonic anhydrase inhibitor, can enhance decongestion in HF by increasing urinary Na and Cl excretion when added to loop diuretics, a mechanism supported by prior studies demonstrating improved urine output and decongestion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!