A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Phantom and Animal Study of a Robot-Assisted, CT-Guided Targeting System using Image-Only Navigation for Stereotactic Needle Insertion without Positional Sensors. | LitMetric

Phantom and Animal Study of a Robot-Assisted, CT-Guided Targeting System using Image-Only Navigation for Stereotactic Needle Insertion without Positional Sensors.

J Vasc Interv Radiol

Department of Vascular and Interventional Radiology, Singapore General Hospital, Singapore; Radiological Sciences Academic Clinical Program, SingHealth-Duke-NUS Academic Medical Centre, Singapore. Electronic address:

Published: November 2022

Purpose: To evaluate the feasibility and accuracy of a robotic system to integrate and map computed tomography (CT) and robotic coordinates, followed by automatic trajectory execution by a robotic arm. The system was hypothesized to achieve a targeting error of <5 mm without significant influence from variations in angulation or depth.

Materials And Methods: An experimental study was conducted using a robotic system (Automated Needle Targeting device for CT [ANT-C]) for needle insertions into a phantom model on both moving patient table and moving gantry CT scanners. Eight spherical markers were registered as targets for 90 insertions at different trajectories. After a single ANT-C registration, the closed-loop software targeted multiple markers via the insertion of robotically aligned 18-gauge needles. Accuracy (distance from the needle tip to the target) was assessed by postinsertion CT scans. Similar procedures were repeated to guide 10 needle insertions into a porcine lung. A regression analysis was performed to test the effect of needle angulation and insertion depth on the accuracy of insertion.

Results: In the phantom model, all needle insertions (median trajectory depth, 64.8 mm; range, 46.1-153 mm) were successfully performed in single attempts. The overall accuracy was 1.36 mm ± 0.53, which did not differ between the 2 types of CT scanners (1.39 mm ± 0.54 [moving patient table CT] vs 1.33 mm ± 0.52 [moving gantry CT]; P = .54) and was not significantly affected by the needle angulation and insertion depth. The accuracy for the porcine model was 9.09 mm ± 4.21.

Conclusions: Robot-assisted needle insertion using the ANT-C robotic device was feasible and accurate for targeting multiple markers in a phantom model.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvir.2022.08.005DOI Listing

Publication Analysis

Top Keywords

phantom animal
4
animal study
4
study robot-assisted
4
robot-assisted ct-guided
4
ct-guided targeting
4
targeting system
4
system image-only
4
image-only navigation
4
navigation stereotactic
4
stereotactic needle
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!