 To evaluate the accuracy and differences between 2 types of metallic markers, sphere, and coin, for radiographic calibration in the preoperative planning of hip arthroplasty.  Four spherical metallic markers and four coins, both 25 mm in diameter, were placed on the greater trochanter, pubic symphysis, between the thighs, and on the table of the exam, for radiographic examination of the hip in 33 patients with hip prosthesis. The prosthesis head was used for calibration and two examiners measured the markers' image diameters, and the results were analyzed statistically.  In the greater trochanter, the sphere and the coin were not visualized in 19 radiographs (57.6%). Between the thighs, the coin marker was not visualized in 13 radiographs (39.4%). In the greater trochanter, the 25-mm accuracy of the coin and the sphere was, respectively, between 57.1 and 63.3% and between 64.3 and 92.9%. The coin between the thighs reached 25-mm accuracy in between 50 and 60% of cases. Over the exam table, the coin and sphere markers reached, respectively, the mean diameters of 22.91 mm and 23 mm, the lowest coefficient of variation, the lowest confidence interval, and the easiest positioning. There was statistical difference between the evaluations of the markers (coin vs. sphere) in all positions (  < 0.032), except for the exam table position (  = 0.083).  The coin between the thighs is the best marker for radiographic calibration in the preoperative planning of hip arthroplasty, and we suggest the use of another coin on the exam table for comparison, considering the 8% reduction in relation to its real size.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9365464PMC
http://dx.doi.org/10.1055/s-0041-1724079DOI Listing

Publication Analysis

Top Keywords

greater trochanter
12
coin sphere
12
coin
8
metallic markers
8
sphere coin
8
visualized radiographs
8
25-mm accuracy
8
sphere
5
difference spherical
4
spherical marker
4

Similar Publications

This study aims to provide an initial database to gain more detailed knowledge of the trabecular and cortical bone structure of pelvic and femur bones in cats and smaller dogs. Additionally, the bony microarchitecture between cats and smaller dogs was compared to identify possible differences between those species. These findings could potentially improve the development of non-cemented total hip replacement (THR).

View Article and Find Full Text PDF

Introduction: As illustrated by the "Walker Dip," there is growing concern regarding the lack of combat casualty care during peacetime. Surgical volume and case complexity are paramount for training and skill sustainment. We sought to quantify the recent orthopedic trauma surgical case load of all military orthopedic surgeons across the Military Health System (MHS).

View Article and Find Full Text PDF

Intra-Individual Stable Isotope Variation Tracks Brazilian Contemporary Dietary and Nutritional Transition.

Am J Biol Anthropol

January 2025

Department of Anthropology, National Museum of Natural History, Smithsonian Institution, Washington, District of Columbia, USA.

Introduction: Contemporary dietary and nutritional transitions are commonplace, but difficult to study directly. In Brazil, and Latin America, this generalized process, leading to current obesity and malnutrition problems, started more than four decades ago. Although body weight and food availability are used to measure changes, not much information on food consumption and nutrition exist.

View Article and Find Full Text PDF

: Hip fractures are prevalent among the elderly and impose a significant burden on healthcare systems due to the associated high morbidity and costs. The increasing use of intramedullary nails for hip fracture fixation has inadvertently introduced risks; these implants can alter bone elasticity and create stress concentrations, leading to peri-implant fractures. The aim of this study is to investigate the outcomes of peri-implant hip fractures, evaluate the potential causes of such fractures, determine the type of treatment provided, assess the outcomes of said treatments, and establish possible improvement strategies.

View Article and Find Full Text PDF

The decision of the Joint Federal Committee on the treatment of hip fractures stipulates that proximal femur fractures must be treated within the first 24 h. This leads to organizational and personnel difficulties in day-to-day care. Therefore, we investigated the question at what times of day we operate to maintain this timeline and whether there is a difference in the outcome for the patients according to treatment hours.

View Article and Find Full Text PDF