A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Upside-down positioning of a peri-interventional cava filter during endovascular thrombectomy of a septic superior vena cava thrombosis. | LitMetric

Upside-down positioning of a peri-interventional cava filter during endovascular thrombectomy of a septic superior vena cava thrombosis.

SAGE Open Med Case Rep

Division of Angiology, Swiss Cardiovascular Center, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.

Published: August 2022

A 43-year-old male patient with advanced colon carcinoma presented with disseminated staphylococcus aureus bacteremia and central venous catheter associated septic thrombosis of the superior vena cava. Despite appropriate antimicrobial therapy and surgical debridement of distant foci, bacteremia persisted, so an endovascular thrombectomy was performed. Contrary to the usual application, the Capturex® peri-interventional cava filter was positioned upside down, in the direction of the blood flow, in the superior vena cava to prevent septic embolism during mechanical thrombectomy. The wall-adherent septic thrombus was mechanically detached using a RAT fragmentation basket® followed by Aspirex® rotational thrombectomy. Final phlebography showed complete thrombus removal. Small thrombus fragments could be demonstrated in the filter after retrieval. The adapted technique of a reverse positioning of the Capturex® filter in the superior vena cava seems feasible and effective.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9364187PMC
http://dx.doi.org/10.1177/2050313X221117333DOI Listing

Publication Analysis

Top Keywords

superior vena
16
vena cava
16
peri-interventional cava
8
cava filter
8
endovascular thrombectomy
8
cava
6
upside-down positioning
4
positioning peri-interventional
4
filter
4
filter endovascular
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!