Selecting a Press-fit Stem for Total Hip Arthroplasty: The Rationale and Evolution of the Modern Femoral Prosthesis.

J Am Acad Orthop Surg

From the University of Vermont Medical Center, Orthopedics and Rehabilitation Center, and the Department of Orthopaedics and Rehabilitation, The Robert Larner, M.D., College of Medicine at The University of Vermont, Burlington, VT.

Published: October 2022

Noncemented press-fit femoral stems predominate in total hip arthroplasty for all age groups with generally excellent long-term survivorship. The 2021 American Joint Replacement Registry reports that 96% of all elective primary total hip arthroplasties used noncemented femoral implant fixation. 1 Today, there are many styles of press-fit stems, each with supposed benefits, based on a range of design philosophies. Design aspects to consider when selecting a stem are numerous, including stem geometry, stem length, collared or collarless, material properties, and surface structure. Although most stem designs demonstrate excellent results, the differences in stem designs are intimately linked to additional factors such as ease of use/implantation, percentage of surface osseointegration, overall bone removal versus bone stock preservation, subsequent femoral stress shielding, and consideration of complexity of later revision. A surgeon with a broad understanding and appreciation of femoral stem designs should be prepared to select between the multitude of options to best serve individual patients.

Download full-text PDF

Source
http://dx.doi.org/10.5435/JAAOS-D-22-00074DOI Listing

Publication Analysis

Top Keywords

total hip
12
stem designs
12
hip arthroplasty
8
stem
7
femoral
5
selecting press-fit
4
press-fit stem
4
stem total
4
arthroplasty rationale
4
rationale evolution
4

Similar Publications

Background: Precise and accurate glenoid preparation is important for the success of shoulder arthroplasty. Despite advancements in preoperative planning software and enabling technologies, most surgeons execute the procedure manually. Patient-specific instrumentation (PSI) facilitates accurate glenoid guide pin placement for cannulated reaming; however, few commercially available systems offer depth of reaming control.

View Article and Find Full Text PDF

Effect of head size, head material, and radiation dose on the repeatability of CT-RSA measurements of femoral head penetration.

J Mech Behav Biomed Mater

January 2025

Division of Orthopaedic Surgery, Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada; Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada. Electronic address:

Background: The risk of early revision of total hip arthroplasty (THA) for polyethylene wear is now low, but there remains a need to perform wear measurements in patients for clinical surveillance. The gold standard of wear measurements has been radiostereometric analysis (RSA), which has limited availability. The use of computed tomography (CT) to perform THA wear measurement was described a decade ago and found to have acceptable accuracy and precision, but high radiation dose was a concern.

View Article and Find Full Text PDF

Introduction: Knee alignment significantly impacts the outcome of total knee arthroplasty (TKA). Understanding patient perceptions of their knee alignment in relation to objective measurements is essential to ensure optimal surgical outcomes and to meet patients' expectations. This study reports patients' perception of pre- and postoperative knee alignment in relation to radiographic alignment measurements.

View Article and Find Full Text PDF

Purpose: The adoption of robotic-assisted total hip arthroplasty (THA) is increasingly widespread, yet its influence on outcomes in outpatient surgery remains uncertain. This study aimed to evaluate whether robotic assistance reduces the rate of 90-day postoperative events in patients undergoing outpatient THA, compared to those in inpatient procedures.

Methods: This historical-prospective cohort study analyzed 706 primary THA cases performed between January 2017 and January 2023 by three senior surgeons.

View Article and Find Full Text PDF

Background: Intraoperative hip capsule management is increasingly recognized as an important component of hip arthroscopy for the prevention of capsular-related instability. The periportal capsulotomy, relative to the interportal capsulotomy, has been proposed as a minimally invasive technique for decreasing postarthroscopy hip instability; however, the biomechanical effects of this technique are not well established.

Purpose/hypothesis: This study aimed to provide a biomechanical characterization of interportal and periportal capsulotomies, helping inform surgeon choice of capsulotomy type and repair, potentially guiding clinical practice in hip arthroscopy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!