Introduction: Estimation of accurate time-integrated activity coefficients (TIACs) and radiation absorbed doses (ADs) is desirable for treatment planning in peptide-receptor radionuclide therapy (PRRT). This study aimed to investigate the accuracy of a simplified dosimetry using a physiologically-based pharmacokinetic (PBPK) model, a nonlinear mixed effect (NLME) model, and single-time-point imaging to calculate the TIACs and ADs of Y-DOTATATE in various organs of dosimetric interest and tumors.
Materials & Methods: Biokinetic data of In-DOTATATE in tumors, kidneys, liver, spleen, and whole body were obtained from eight patients using planar scintigraphic imaging at T1 = (2.9 ± 0.6), T2 = (4.6 ± 0.4), T3 = (22.8 ± 1.6), T4 = (46.7 ± 1.7) and T5 = (70.9 ± 1.0) h post injection. Serum activity concentration was measured at 5 and 15 min; 0.5, 1, 2, and 4 h; and 1, 2, and 3 d p.i.. A published PBPK model for PRRT, NLME, and a single-time-point imaging datum at different time points were used to calculate TIACs in tumors, kidneys, liver, spleen, whole body, and serum. Relative deviations (RDs) (median [min, max]) between the calculated TIACs from single-time-point imaging were compared to the TIACs calculated from the all-time-points fit. The root mean square error (RMSE) of the difference between the computed ADs from the single-time-point imaging and reference ADs from the all-time point fittings were analyzed. A joint root mean square error RMSE of the ADs was calculated with the RSME from both the tumor and kidneys to sort the time points concerning accurate results for the kidneys and tumor dosimetry. The calculations of TIACs and ADs from the single-time-point dosimetry were repeated using the sum of exponentials (SOE) approach introduced in the literature. The RDs and the RSME of the PBPK approach in our study were compared to the SOE approach.
Results: Using the PBPK and NLME models and the biokinetic measurements resulted in a good fit based on visual inspection of the fitted curves and the coefficient of variation CV of the fitted parameters (<50%). T4 was identified being the time point with a relatively low median and range of TIACs RDs, i.e., 5 [1, 21]% and 2 [-15, 21]% for kidneys and tumors, respectively. T4 was found to be the time point with the lowest joint root mean square error RMSE of the ADs. Based on the RD and RMSE, our results show a similar performance as the SOE and NLME model approach.
Summary: In this study, we introduced a simplified calculation of TIACs/ADs using a PBPK model, an NLME model, and a single-time-point measurement. Our results suggest a single measurement might be used to calculate TIACs/ADs in the kidneys and tumors during PRRT.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10082376 | PMC |
http://dx.doi.org/10.1016/j.zemedi.2022.06.004 | DOI Listing |
Eur J Nucl Med Mol Imaging
December 2024
Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 20, 3010, Bern, Switzerland.
Introduction: Despite the potential of dosimetry in optimizing personalized radiopharmaceutical therapy (RPT), its limited clinical implementation impedes the development of simplified protocols for routine adoption. However, simplifications may introduce errors in dosimetry, prompting questions about their impact on clinical practice.
Materials And Methods: In this retrospective study, we analyzed data from 21 patients diagnosed with metastatic castration-resistant prostate cancer (mCRPC) who underwent multiple cycles of Lu-PSMA-617 RPT treatment.
Phys Med
December 2024
Medical Radiation Physics, Department of Nuclear Medicine, Ulm University, Ulm, Germany.
Purpose: This study aimed to determine the effect of model selection on simplified dosimetry for the kidneys using Bayesian fitting (BF) and single-time-point (STP) imaging.
Methods: Kidney biokinetics data of [Lu]Lu-PSMA-617 from mHSPC were collected using SPECT/CT after injection of (3.1 ± 0.
Stroke
January 2025
Department of Epidemiology (D.B., F.J.W., A.H., M.A.I., M.W.V.), Erasmus MC University Medical Center, Rotterdam, the Netherlands.
Crit Care
December 2024
Department of Anesthesiology, Intensive Care, Emergency and Pain Medicine, University Hospital Würzburg, Würzburg, Germany.
Background: Loss of hemodynamic coherence is a phenomenon in critically ill patients. Due to inflammatory events and endothelial remodeling, macro- and microhemodynamics are decoupled from each other, resulting in microcirculatory disturbances and end organ ischemia despite adequate vital parameters. So far, quantification of perfusion of vessels with < 100 μm diameter on the intensive care unit (ICU) was regularly performed with incident darkfield (IDF) microscopy.
View Article and Find Full Text PDFPain Med
November 2024
Department of Physical Medicine and Rehabilitation, University of Michigan, 325 E Eisenhower Parkway, Ann Arbor, Michigan, 48108.
Objective: To compare localized (primary) and widespread (secondary) hyperalgesia using pressure pain threshold (PPT) of patients with normal imaging findings, rotator cuff tear, or other pathologies.
Design: This was a cross-sectional design with data collected at a single time point.
Setting: This study was performed at two large, urban, academic medical centers.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!