A portable device is conducive to the on-site detection of heavy metal ions at trace level in food and the prevention of related food safety issues. In this work, an electrochemical device stacked up with flat electrodes was developed for the detection of Pb and Cd. The top layer of the device is a carbon paper as working electrode, which is modified with amino functionalized cobalt-based metal-organic framework and gold nanoparticles. The bottom layer was constructed with the carbon counter electrode and Ag/AgCl reference electrode, and a punched sample cell (Φ = 8 mm) was in the middle. The proposed method could simultaneously determinate Pb and Cd via anodic stripping voltammetry with the detection limit of 7.0 × 10 ng mL and 1.1 × 10 ng mL, and was applied in real food samples (drinking water, juice, tea, grain, fruits, vegetables, liver and aquatic products) with the recovery of 91.2-105.4 % and 90.2-111.2 %, respectively.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.foodchem.2022.133822 | DOI Listing |
Nat Commun
January 2025
National Key Laboratory of Advanced Micro and Nano Manufacture Technology, School of Materials Science and Engineering, Peking University, Beijing, China.
On-site or in-sensor biosignal transduction and amplification can offer several benefits such as improved signal quality, reduced redundant data transmission, and enhanced system integration. Ambipolar organic electrochemical transistors (OECTs) are promising for this purpose due to their high transconductance, low operating voltage, biocompatibility, and suitability for miniaturized amplifier design. However, limitations in material performance and stability have hindered their application in biosignal amplification.
View Article and Find Full Text PDFTalanta
December 2024
NanoBiosensors and Biodevices Lab, School of Medical Science and Technology, Indian Institute of Technology Kharagpur, West Bengal, 721302, India. Electronic address:
This work presents a robust strategy for quantifying overlapping electrochemical signatures originating from complex mixtures and real human plasma samples using nickel-based electrochemical sensors and machine learning (ML). This strategy enables the detection of a panel of analytes without being limited by the selectivity of the transducer material and leaving accommodation of interference analysis to ML models. Here, we fabricated a non-enzymatic electrochemical sensor for L-lactic acid detection in complex mixtures and human plasma samples using nickel oxide (NiO) nanoparticle-modified glassy carbon electrodes (GCE).
View Article and Find Full Text PDFBiosens Bioelectron
December 2024
Department of Biological Science and Technology, Institute of Molecular Medicine and Bioengineering, Center for Intelligent Drug Systems and Smart Bio-devices (IDS(2)B), Yang Ming Chiao Tung University, Hsinchu 300, Taiwan; Department of Biomedical Science and Environmental Biology, School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung 807, Taiwan. Electronic address:
Anti-mullerian hormone (AMH) detection receives much attention since it is used as an ideal biomarker for quantitative assessment of ovarian reserve. The present study proposed a first report on the use of MOF-on-MOF as an electrochemical sensor for recognizing AMH in buffer and serum media. The MOF-on-MOF, MIL-88 B@UiO66NH was synthesized by the internal extended growth method (IEGM) involving MIL-88 B on UiO66NH by in situ method for the first time.
View Article and Find Full Text PDFJ Environ Manage
January 2025
School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, PR China; Key Laboratory of Environmental Engineering, Shaanxi Province, Xi'an University of Architecture and Technology, Xi'an, 710055, PR China.
A self-driven electrochemical system (SDES) was utilized to treat anaerobic digestate wastewater, aiming to achieve wastewater resource utilization and energy generation. The efficiencies of pollutant removal, resource recovery, and energy production were enhanced by adjusting device parameters (anode area, external resistance, and electrode spacing). The high pollutant removal rates and struvite purity were achieved with the magnesium anode area of 15 cm, external resistance of 10 Ω, and electrode spacing of 10 cm.
View Article and Find Full Text PDFRecent Pat Nanotechnol
January 2025
State Key Laboratory of Vanadium and Titanium Resources Comprehensive Utilization, ANSTEEL Research Institute of Vanadium & Titanium (Iron & Steel), Chengdu 610031, China.
One-dimensional (1D) vanadium-based nanostructures have advantageous properties and are showing emerging critical applications in the fields of catalysis, smart devices, and electrochemical energy storage. We herein timely gave an overview of the 1D vanadium pentoxide (VO)-based nanomaterials for these promising applications, especially regarding the merits of different synthetic methods, structures and properties combined with recent research frontiers in advanced energy storage, including batteries, supercapacitors and like. The high capacity, high rate and flexibility of 1D VO-based nanomaterials endow them with great potential in high-energy-density, high-power energy devices and specific/harsh environments.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!