To investigate the impact of the iris and ciliary body morphology on the central vault after phakic posterior chamber intraocular lens (pIOL) implantation. This research was based on the retrospective analysis of 123 patients (123 eyes) who underwent pIOL implantation in the Department of Ophthalmology, Affiliated Hospital of Qingdao University between June 2018 and June 2020. The anterior segment structure was observed with an ultrasound biomicroscope before surgery, and all morphological parameters of the iris and ciliary body were measured manually using the ImageJ software, including iris span (IS), iris convexity (IC), iris-ciliary body contact distance (ICCD) and iris-lens contact distance (ILCD). The ICCD was divided into Q1, Q2 and Q3 groups according to the equidistant distance of 0.36 mm. The lens thickness was measured with the IOLMaster. The horizontal corneal diameter and anterior chamber depth were measured using the Pentacam. The central vaults were measured by optical coherence tomography at 1 week, 3 months and 1 year after surgery. The relationships between vault values and preoperative parameters of the anterior segment were evaluated using the Pearson correlation analysis, Spearman correlation analysis, and multiple linear regression. The repeated measures ANOVA was applied to identify changes of vault values over time. The mean values of the vaults at 1 week, 3 months and 1 year after surgery were (723±265) μm, (642±255) μm and (613±280) μm, respectively. The difference among them was statistically significant (=50.143, <0.001). The vaults continued to decline within 1 year after pIOL implantation, and the total decline was (122±86) μm. The vaults declined by (69±98) μm from postoperative 1 week to 3 months and by (52±54) μm from postoperative 3 months to 1 year. The regression formula showed that the pIOL size and ILCD were positively related with the vault, while the LT, IS and IC were negatively related with the vault at 1 week postoperatively (adjusted ²=0.404, <0.001). The pIOL size and ILCD were positively related with the vault, while the IS and IC were negatively related with the vault at 3 months postoperatively (adjusted ²=0.342, <0.001). The pIOL size was positively related with the vault, while the IS and IC were negatively related with the vault at 1 year postoperatively (adjusted ²=0.661, <0.001). The vault values were higher in group Q3 compared to group Q1 at every timepoint, and the vault value was higher in group Q2 compared to Q1 at 1 year postoperatively. In the early postoperative period, eyes with a larger pIOL, shorter iris span, longer contact distance between the iris and ciliary body, and longer contact distance between the iris and lens were associated with a higher rate of excessive vaults. Meanwhile, eyes with a thicker lens and larger iris reverse convexity were more likely to obtain insufficient vaults. Within one year after surgery, the pIOL size, IS, IC and ICCD continued to impact on the vault. The ICCD, ILCD and IC can reflect the posterior chamber volume and change the haptic location and force, thus affecting the vault.

Download full-text PDF

Source
http://dx.doi.org/10.3760/cma.j.cn112142-20220214-00060DOI Listing

Publication Analysis

Top Keywords

iris ciliary
12
ciliary body
12
central vault
8
posterior chamber
8
intraocular lens
8
piol implantation
8
anterior segment
8
contact distance
8
week months
8
months year
8

Similar Publications

Anterior segment dysgenesis exerts its influence on a diverse array of ocular structures, encompassing the cornea, iris, ciliary body, anterior chamber and lens. We present a 20-month-old boy with bilateral corneal opacity. The visual acuity (VA) was 6/480 in both eyes.

View Article and Find Full Text PDF

Pseudoexfoliation syndrome (PXS) is an age-related fibrillopathy where fibrillar exfoliation material accumulates and deposits in ocular and extra-ocular tissue. Within the eye, this substance accumulates on the ocular surface and in the anterior segment of the eye, impacting ocular structures such as the conjunctiva, Tenon's capsule, sclera, cornea, iris, ciliary body, trabecular meshwork, and lens. This review aims to collate the current literature on how each anatomical part of the eye is affected by PXS, with a strong focus on molecular changes.

View Article and Find Full Text PDF

Purpose: To develop an artificial intelligence algorithm to automatically identify the anterior segment structures and assess multiple parameters of primary angle closure disease (PACD) in ultrasound biomicroscopy (UBM) images.

Design: Development and validation of an artificial intelligence algorithm for UBM images.

Methods: 2339 UBM images from 592 subjects were collected for algorithm development.

View Article and Find Full Text PDF

Introduction: Cataract surgery has been reported to have a reducing effect on intraocular pressure (IOP) in glaucomatous and non-glaucomatous eyes. This effect seems to be more noticeable in eyes with narrow angles (NAs) than in eyes with open angles (OAs). Decrease in IOP may be a result of the increase in anterior chamber angle (ACA) and Schlemm canal (SC) after cataract surgery.

View Article and Find Full Text PDF

Persistent hypotony following Tanito microhook trabeculotomy (TMH) is rare but may occur due to the development of cyclodialysis clefts. We report a case of a Japanese man in his 40s who developed persistent hypotony and hypotony maculopathy after TMH in the left eye. Fourteen months after the surgery, the patient was referred to our institution due to prolonged hypotony that remained undiagnosed and untreated despite evaluations with gonioscopy and anterior segment optical coherence tomography (AS-OCT) at the referring clinic.

View Article and Find Full Text PDF