Technetium Tc 99m tilmanocept fails to detect sentinel lymph nodes in endometrial cancer.

Gynecol Oncol Rep

Department of Obstetrics and Gynecology, Division of Gynecologic Oncology, Stanford School of Medicine, Stanford Women's Cancer Center and Stanford Cancer Institute, 300 Pasteur Drive, Stanford, CA 94305, USA.

Published: October 2022

Background: Technetium Tc 99m tilmanocept is a synthetic radiotracer specifically designed for sentinel lymph node (SLN) mapping that has been FDA-approved in breast cancer, melanoma, and head and neck cancer. No published studies exist for the use of this radiotracer in endometrial cancer.

Objective: The primary objective was to determine the detection rate of bilateral SLNs in endometrial cancer with the concurrent use of technetium Tc 99m tilmanocept and ICG.

Methods: An open-label, single cohort, prospective feasibility study was conducted with participants receiving preoperative cervical injections of technetium Tc 99m tilmanocept followed by subsequent imaging and SPECT/CT. Intraoperative ICG injections were administered for all patients with near-infrared imaging used to visualize lymphatic vessels and nodes. A laparoscopic gamma counter was used to detect radioactive SLN intraoperatively.

Results: All six evaluated patients had FIGO grade 1 or 2 endometrioid histology. Stage IA/IB were in 33% and 66% of patients, respectively. Tilmanocept did not map any SLN in the first six patients but instead showed retention of the tracer in the cervical stroma, leading to study discontinuation for futility. ICG mapped bilateral SLN in all patients with the most common location being the external iliac region, followed by the obturator and common iliac areas. All patients had CD206 positive staining throughout the full wall thickness of ectocervix, transformation zone, endocervix, and lymphatic vessels. No patients experienced adverse events.

Conclusion: Technetium Tc 99m tilmanocept did not detect SLN in early stage endometrial cancers and is unlikely to improve bilateral detection rate compared to ICG alone. ICG remains a standard technique for SLN detection in low stage, low grade endometrial cancer.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9361318PMC
http://dx.doi.org/10.1016/j.gore.2022.101054DOI Listing

Publication Analysis

Top Keywords

technetium 99m
20
99m tilmanocept
20
endometrial cancer
12
sentinel lymph
8
detection rate
8
lymphatic vessels
8
sln patients
8
patients
7
tilmanocept
6
sln
6

Similar Publications

Objective: The aim of the study is to assess the diagnostic accuracy of 4-dimensional computed tomography (4D-CT) scans for patients with primary hyperparathyroidism (pHPT) after negative or inconclusive Technetium-99m sestamibi single-photon emission computed tomography scan.

Methods: A literature search of several databases was conducted from inception to August 2023. Eligible studies reported adult patients (>18 years old) who underwent 4D-CT after negative or inconclusive sestamibi results.

View Article and Find Full Text PDF

Background The sentinel lymph node biopsy (SLNB) is the standard method used to determine the stage of breast cancer in patients with no clinical signs of axillary involvement. The current gold standard for the intraoperative assessment of the axilla involves the use of dual radioisotope and patent blue dye. However, researchers have been studying the use of superparamagnetic iron oxide Magtrace® (Endomagnetics Limited, Cambridge, United Kingdom) agents as an alternative to overcome the limitations of the standard SLNB technique.

View Article and Find Full Text PDF

This article presents 582 bone scan images from 291 adult patients who attended the Nuclear Medicine Service at the Instituto de Investigaciones en Ciencias de la Salud (IICS) of the Universidad Nacional de Asunción (UNA), Paraguay, between 2020 and 2024. The images were acquired using trimodal SPECT-CT-PET equipment, model AnyScan SCP, and the MEDISO brand. Approximately 20 mCi of technetium-99m methylene diphosphonate (Tc-MDP) was administered to each patient, producing whole-body planar images in anterior and posterior projections of the axial and appendicular skeleton with a resolution of 256 × 1024 pixels.

View Article and Find Full Text PDF

Introduction: This study examined factors that affected sentinel lymph node (SLN) identification of patients with endometrial cancer having a preoperative estimation of low recurrent risk.

Methods: This study included 97 patients with endometrial cancer who attempted to identify SLN using a uterine cervical injection of technetium-99 m phytate under laparoscopic or robotic-assisted surgery at our institute. A preoperative single photon emission computed tomography (SPECT) and intraoperative gamma probe were used to detect hot nodes.

View Article and Find Full Text PDF

Technetium-99m (Tc-99m) is the most employed radionuclide in nuclear imaging diagnostics worldwide for many diseases. The ideal physiochemical properties of Tc-99m (such as half-life and pure gamma energy) make it favorable for Single Photon Emission Computed Tomography (SPECT). In this study, we aim to expand the utilization of Tc-99m radiopharmaceutical toward prostate cancer diagnostics which is currently no FDA approved products and has been intensively examined for a potential candidate.