Motion platforms have been used in simulators of all types for several decades. Since it is impossible to reproduce the accelerations of a vehicle without limitations through a physically limited system (platform), it is common to use washout filters and motion cueing algorithms (MCA) to select which accelerations are reproduced and which are not. Despite the time that has passed since their development, most of these algorithms still use the classical washout algorithm. In the use of these MCAs, there is always information that is lost and, if that information is important for the purpose of the simulator (the training simulators), the result obtained by the users of that simulator will not be satisfactory. This paper shows a case study where a BMW 325Xi AUT fitted with a sensor, recorded the accelerations produced in all degrees of freedom (DOF) during several runs, and data have been introduced in mathematical simulation software (washout + kinematics + actuator simulation) of a 6DOF motion platform. The input to the system has been qualitatively compared with the output, observing that most of the simulation adequately reflects the input to the system. Still, there are three events where the accelerations are lost. These events are considered by experts to be of vital importance for the outcome of a learning process in the simulator to be adequate.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9371164 | PMC |
http://dx.doi.org/10.3390/s22155837 | DOI Listing |
Clin Lung Cancer
December 2024
Department of Radiation Oncology, University of California Davis Comprehensive Cancer Center, Sacramento, CA. Electronic address:
An Bras Dermatol
January 2025
Santa Casa de Porto Alegre, Porto Alegre, RS, Brazil.
An Bras Dermatol
January 2025
Department of Pathology, Faculty of Medical Sciences, Universidade Estadual de Campinas, Campinas, SP, Brazil.
Med Dosim
January 2025
Department of Radiation Oncology, Peking University First Hospital, Beijing, China. Electronic address:
This study presents a patient with a PET-CT detected residual lacrimal sac tumor who was treated with intensity modulated proton therapy (IMPT) and concurrent chemotherapy. The patient a 49-year-old male diagnosed with squamous cell carcinoma of the left lacrimal sac had under-went endoscopic surgery. Postoperative PET-CT implied tumor residual in the left lacrimal sac.
View Article and Find Full Text PDFRev Esp Cardiol (Engl Ed)
January 2025
Unidad de Arritmias, Hospital Universitario Central de Asturias, Instituto de Investigación Sanitaria del Principado de Asturias, Oviedo, Asturias, Spain; Unidad de Arritmias, Instituto de Investigación Sanitaria Hospital Clínico San Carlos (IdISSC), Madrid, Spain; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Spain.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!