UAV-Based Smart Educational Mechatronics System Using a MoCap Laboratory and Hardware-in-the-Loop.

Sensors (Basel)

Posgrado en Ingeniería y Tecnología Aplicada, Unidad Académica de Ingeniería Eléctrica, Universidad Autónoma de Zacatecas, Zacatecas 98000, Zacatecas, Mexico.

Published: July 2022

Within Industry 4.0, drones appear as intelligent devices that have brought a new range of innovative applications to the industrial sector. The required knowledge and skills to manage and appropriate these technological devices are not being developed in most universities. This paper presents an unmanned aerial vehicle (UAV)-based smart educational mechatronics system that makes use of a motion capture (MoCap) laboratory and hardware-in-the-loop (HIL) to teach UAV knowledge and skills, within the Educational Mechatronics Conceptual Framework (EMCF). The macro-process learning construction of the EMCF includes concrete, graphic, and abstract levels. The system comprises a DJI Phantom 4, a MoCap laboratory giving the drone location, a Simulink drone model, and an embedded system for performing the HIL simulation. The smart educational mechatronics system strengthens the assimilation of the UAV waypoint navigation concept and the capacity for drone flight since it permits the validation of the physical drone model and testing of the trajectory tracking control. Moreover, it opens up a new range of possibilities in terms of knowledge construction through best practices, activities, and tasks, enriching the university courses.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9370916PMC
http://dx.doi.org/10.3390/s22155707DOI Listing

Publication Analysis

Top Keywords

educational mechatronics
16
smart educational
12
mechatronics system
12
mocap laboratory
12
uav-based smart
8
laboratory hardware-in-the-loop
8
knowledge skills
8
drone model
8
system
5
educational
4

Similar Publications

An integrated magnetoimpedance biosensor microfluidic magnetic platform for the evaluation of the cardiac marker cTnI.

Anal Methods

January 2025

Microelectronic Research & Development Center, School of Mechatronics Engineering and Automation, Shanghai University, Shanghai 200444, China.

An integrated magnetoimpedance (MI) biosensor microfluidic magnetic platform was proposed for the evaluation of the cardiac marker, cardiac troponin I (cTnI). This bioanalyte evaluation platform mainly comprised three external permanent magnets (PMs), one MI element, two peelable SiO film units and a microfluidic chip (MFC). The MI element was made of micro-electro-mechanical system (MEMS)-based multilayered [Ti (6 nm)/FeNi (100 nm)]/Cu (400 nm)/[Ti (6 nm)/FeNi (100 nm)] thin films and designed as meander structures with closed magnetic flux.

View Article and Find Full Text PDF

Milling chatter, a form of self-excited vibration, can cause significant damage in machining and manufacturing processes. By selecting appropriate milling parameters, milling chatter can be effectively mitigated without sacrificing milling efficiency. Within the framework of the semi-discretization scheme, this paper introduces the Newton-Simpson-based predictor-corrector methods to compute milling stability lobe diagrams.

View Article and Find Full Text PDF

Self-assembled peptide microtubes (SPMTs)/SnO sensors for enhanced room-temperature gas detection under visible light illumination.

Talanta

December 2024

Engineering Research Center of Smart Microsensors and Microsystems, Ministry of Education, College of Electronics and Information, Hangzhou Dianzi University, Hangzhou, Zhejiang, 310018, China; China-Israel Polypeptide Device and Application Technology Joint Research Center, Hangzhou, 310027, China. Electronic address:

Nitrogen dioxide (NO) is an important contaminant that poses a severe threat to environmental sustainability. Traditional inorganic NO gas detectors are generally used under harsh operating conditions and employ environmentally unfriendly resources, thus preventing widespread practical applications. Herein, self-assembled peptide microtubes (SPMTs) are combined with SnO nanoparticles (NPs) to develop a bioinspired NO gas sensor.

View Article and Find Full Text PDF

Ultrasonic detection of wrinkles in composites with gradual phase shift migration.

Ultrasonics

December 2024

School of Mechatronic & Automation Engineering, Shanghai University, Shanghai 200444, China; Key Laboratory of Silicate Cultural Relics Conservation (Shanghai University), Ministry of Education, China. Electronic address:

Fiber reinforced polymer composites (FRPs) are essential for various industrial fields, but wrinkles inside will greatly reduce their mechanical properties. Full-matrix capture (FMC) is a popular data structure for ultrasonic phased array imaging in composites. However, such structure may lead to data redundancy and noise interference.

View Article and Find Full Text PDF

This work aims to address key issues in the ballistic performance of ceramic-based composite armor, particularly at the joints of spliced ​​bulletproof panels. The edge structure of C/C-SiC ceramic plates and ultra-high molecular weight polyethylene is redesigned to superimpose the joint areas. These structurally optimized composite pads are examined by numerical simulation of impact dynamics to understand their anti-penetration performance whose accuracy is then validated by live fire tests.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!