This paper proposes a simple, high-efficiency refractive index (RI) sensor, with a structure based on the planar lightwave circuit (PLC) probe type. The optical sensor has a 1 × 2 splitter structure with reference and sensing channels, each consisting of a U-shaped waveguide structure that is configured by connecting C bends. This design allows for the sensor device to have a probe structure wherein the surface interconnected with activity devices (i.e., an optical source and optical detector) is placed on one side. The reference channel is bent with a minimum optical loss, and the sensing channel has a bent structure, involving a C-bend waveguide with a maximum loss. The C-bend waveguide with a maximum loss is conformally aligned to have a trench structure with the same bending radius, designed to selectively expose the sidewall of the core layer. The local index contrast varies depending on the material in contact with the trench, resulting in a change in the optical output power of the waveguide. The sensitivity of the proposed sensor was 0 and 2070 μW/refractive index unit (RIU) for the reference and sensing channels, respectively, as the RI changed from 1.385 to 1.445 at a 1550 nm wavelength. These results suggest that the proposed structure enables efficient RI measurement through the use of a simple dip-type method.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9370853PMC
http://dx.doi.org/10.3390/s22155672DOI Listing

Publication Analysis

Top Keywords

refractive sensor
8
reference sensing
8
sensing channels
8
channel bent
8
c-bend waveguide
8
waveguide maximum
8
maximum loss
8
structure
7
sensor
5
waveguide
5

Similar Publications

In this paper, a dual-parameter liquid level and refractive index (R.I.) sensor is fabricated using three pieces of bare polymer optical fibers (POFs), which can independently and simultaneously sense the liquid level and R.

View Article and Find Full Text PDF

An ultrasensitive angular interrogation metasurface sensor based on the TE mode surface lattice resonance.

Microsyst Nanoeng

January 2025

National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Beijing, 100871, PR China.

The localized surface plasmon resonance metasurface is a research hotspot in the sensing field since it can enhance the light-matter interaction in the nanoscale, but the wavelength sensitivity is far from comparable with that of prism-coupled surface plasmon polariton (SPP). Herein, we propose and demonstrate an ultrasensitive angular interrogation sensor based on the transverse electric mode surface lattice resonance (SLR) mechanism in an all-metal metasurface. In theory, we derive the sensitivity function in detail and emphasize the refraction effect at the air-solution interface, which influences the SLR position and improves the sensitivity performance greatly in the wide-angle.

View Article and Find Full Text PDF

In the case of waveguide-based devices, once they are fabricated, their optical properties are already determined and cannot be dynamically controlled, which limits their applications in practice. In this paper, an isosceles triangular-coupling structure which consists of an isosceles triangle coupled with a two-bus waveguide is proposed and researched numerically and theoretically. The coupled mode theory (CMT) is introduced to verify the correctness of the simulation results, which are based on the finite difference time domain (FDTD).

View Article and Find Full Text PDF

Comparative Analysis of Physiological Vergence Angle Calculations from Objective Measurements of Gaze Position.

Sensors (Basel)

December 2024

Department of Optometry and Vision Science, Faculty of Science and Technology, University of Latvia, Jelgavas Street 1, LV-1004 Riga, Latvia.

Eccentric photorefractometry is widely used to measure eye refraction, accommodation, gaze position, and pupil size. While the individual calibration of refraction and accommodation data has been extensively studied, gaze measurements have received less attention. PowerRef 3 does not incorporate individual calibration for gaze measurements, resulting in a divergent offset between the measured and expected gaze positions.

View Article and Find Full Text PDF

A core dielectric cylindrical rod wrapped in a dielectric circular pipe whose outer surface is enclosed by a helical conducting strip grating that is skewed along the axial direction is herein analyzed using the asymptotic strip boundary conditions along with classical vector potential analysis. Targeted for use as a cylindrical holographic antenna, the resultant field solutions facilitate the aperture integration of the equivalent cylindrical surface currents to obtain the radiated far fields. As each rod section of a certain skew angle exhibits a distinct modal attribute; this topology allows for the distribution of the cylindrical surface impedance via the effective refractive index to be modulated, as in gradient-index (GRIN) materials.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!