Application of Fourier Transform Infrared (FT-IR) Spectroscopy, Multispectral Imaging (MSI) and Electronic Nose (E-Nose) for the Rapid Evaluation of the Microbiological Quality of Gilthead Sea Bream Fillets.

Foods

Laboratory of Microbiology and Biotechnology of Foods, Department of Food Science and Human Nutrition, School of Food and Nutritional Sciences, Agricultural University of Athens, Iera Odos 75, 11855 Athens, Greece.

Published: August 2022

AI Article Synopsis

  • * FT-IR spectroscopy showed the best performance in predicting total viable counts (TVC), with high coefficients of determination (R values of 0.98 and 0.94) and low errors, while MSI and E-nose were less accurate.
  • * The findings indicate that FT-IR is a reliable method for quickly determining the microbiological quality of fish fillets compared to the other techniques tested.

Article Abstract

The potential of Fourier transform infrared (FT-IR) spectroscopy, multispectral imaging (MSI), and electronic nose (E-nose) was explored in order to determine the microbiological quality of gilthead sea bream () fillets. Fish fillets were maintained at four temperatures (0, 4, 8, and 12 °C) under aerobic conditions and modified atmosphere packaging (MAP) (33% CO, 19% O, 48% N) for up to 330 and 773 h, respectively, for the determination of the population of total viable counts (TVC). In parallel, spectral data were acquired by means of FT-IR and MSI techniques, whereas the volatile profile of the samples was monitored using an E-nose. Thereafter, the collected data were correlated to microbiological counts to estimate the TVC during fish fillet storage. The obtained results demonstrated that the partial least squares regression (PLS-R) models developed on FT-IR data provided satisfactory performance in the estimation of TVC for both aerobic and MAP conditions, with coefficients of determination (R) for calibration of 0.98 and 0.94, and root mean squared error of calibration (RMSE) values of 0.43 and 0.87 log CFU/g, respectively. However, the performance of the PLS-R models developed on MSI data was less accurate with R values of 0.79 and 0.77, and RMSE values of 0.78 and 0.72 for aerobic and MAP storage, respectively. Finally, the least satisfactory performance was observed for the E-nose with the lowest R (0.34 and 0.17) and the highest RMSE (1.77 and 1.43 log CFU/g) values for aerobic and MAP conditions, respectively. The results of this work confirm the effectiveness of FT-IR spectroscopy for the rapid evaluation of the microbiological quality of gilthead sea bream fillets.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9367857PMC
http://dx.doi.org/10.3390/foods11152356DOI Listing

Publication Analysis

Top Keywords

ft-ir spectroscopy
12
microbiological quality
12
quality gilthead
12
gilthead sea
12
sea bream
12
bream fillets
12
aerobic map
12
fourier transform
8
transform infrared
8
infrared ft-ir
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!