Purpose: The purpose of this study was to examine the effect of subcutaneous adipose tissue (SCAT) thickness and rectus femoris (RF) muscle thickness on RF and vastus intermedius (VI) echo intensity using human cadavers.
Methods: The echo intensity of the RF and VI was measured in 11 legs of seven cadavers under three conditions: intact condition (Model 1), SCAT removed (Model 2), and SCAT and RF removed (Model 3).
Results: RF echo intensity in Model 1 (69.2 ± 20.3 a.u.) was significantly lower than that in Model 2 (83.4 ± 15.9 a.u.) (P = 0.003). VI echo intensity in Models 1 to 3 showed similar results to RF echo intensity (P = 0.003 to 0.001). Regarding the relationship between VI echo intensity and VI muscle thickness, the regression lines shifted upward in a parallel fashion in the order Model 1, Model 2, and Model 3. Multiple regression analysis revealed that the variation in RF echo intensity was explained by RF muscle thickness (P = 0.036) and SCAT thickness (P = 0.001), while the variation in VI echo intensity was explained by RF muscle thickness (P = 0.035).
Conclusion: These results suggest that SCAT thickness and RF muscle thickness induce lower RF echo intensity, while RF muscle thickness induces lower VI echo intensity.