Objectives: Ankle radiographs are among the most commonly obtained trauma images in the pediatric population, with the standard 3 views (AP/mortise [M]/lateral [L]) routinely ordered in the emergency department. The purpose of this study was to compare the diagnostic accuracy, sensitivity, and specificity of sets of 2 views (AP/L or M/L) with the standard 3 views.

Methods: One hundred twenty sets of ankle radiographs of skeletally immature patients obtained in the emergency department of a level 1 pediatric trauma center were used. These included sets with and without fractures. Sets of 3 and 2 views were reviewed by pairs of pediatric-trained orthopedic surgeons, radiologists, and emergency physicians. Each completed 3 randomized viewing sessions where all possible combinations for each set of radiographs were reviewed. Diagnoses for the 3 sets of views were compared for accuracy, sensitivity, and specificity.

Results: Overall accuracy, sensitivity, and specificity for all reviewers were as follows: AP/M/L 74%, 94%, and 90%, AP/L 71%, 90%, and 94%, as well as M/L 69%, 90%, and 91%. P values for accuracy, sensitivity, and specificity of AP/L and M/L compared with 3 views were 0.34, 0.04, and 0.52, as well as 0.04, 0.004, and 1.00, respectively.

Conclusions: In skeletally immature patients, statistically significant differences in accuracy were obtained when comparing the standard 3 AP/M/L views with more limited M/L views, suggesting that this set of 2 views is not as accurate. Differences in sensitivity of limited views were also statistically significant. Conversely, differences in accuracy between the standard 3 views and AP/Lateral views were not statistically significant. While more limited AP/L views may be comparable in accuracy and specificity and lead to dramatically decreased radiation and costs, this can be at the expense of less diagnostic sensitivity and increased risk of misdiagnosing or missing certain fractures.

Level Of Evidence: Level III.

Download full-text PDF

Source
http://dx.doi.org/10.1097/PEC.0000000000002810DOI Listing

Publication Analysis

Top Keywords

accuracy sensitivity
16
views
13
sensitivity specificity
12
sets views
12
ankle radiographs
8
standard views
8
emergency department
8
ap/l m/l
8
skeletally immature
8
immature patients
8

Similar Publications

Assessing modified HEART scores with high-sensitivity troponin for low-risk chest pain in the emergency department.

Intern Emerg Med

December 2024

Department of Emergency Medicine, JPS Health Network, 1500 S. Main St., Fort Worth, TX, 76104, USA.

The accuracy of using HEART (history, electrocardiogram, age, risk factors, and troponin) scores with high-sensitivity cardiac troponin (hs-cTn) to risk stratify emergency department (ED) chest pain patients remains uncertain. We aim to compare the performance accuracy of determining major adverse cardiac event (MACE) among three modified HEART (mHEART) scores with the use of hs-cTn to risk stratify ED chest pain patients. This retrospective single-center observational study included ED patients with suspected acute coronary syndrome who had HEAR scores calculated and at least one hs-cTnI result.

View Article and Find Full Text PDF

Acoustic Exaggeration Enhances Speech Discrimination in Young Autistic Children.

Autism Res

December 2024

Psychiatry and Addictology Department, CIUSSS-NIM Research Center, University of Montreal, Montreal, Quebec, Canada.

Child-directed speech (CDS), which amplifies acoustic and social features of speech during interactions with young children, promotes typical phonetic and language development. In autism, both behavioral and brain data indicate reduced sensitivity to human speech, which predicts absent, decreased, or atypical benefits of exaggerated speech signals such as CDS. This study investigates the impact of exaggerated fundamental frequency (F0) and voice-onset time on the neural processing of speech sounds in 22 Chinese-speaking autistic children aged 2-7 years old with a history of speech delays, compared with 25 typically developing (TD) peers.

View Article and Find Full Text PDF

Background: Metagenomic next-generation sequencing (mNGS) has emerged as a promising tool in clinical practice due to its unbiased approach to pathogen detection. Its diagnostic performance in pulmonary tuberculosis (PTB), however, remains to be fully evaluated.

Objective: This study aims to systematically review and Meta-analyze the diagnostic accuracy of mNGS in patients with PTB.

View Article and Find Full Text PDF

Gene expression profiling for the diagnosis of male breast cancer.

BMC Cancer

December 2024

Department of Pathology, Fudan University Shanghai Cancer Center, and Shanghai Key Laboratory of Medical Epigenetics, International Co-laboratory of Medical Epigenetics and Metabolism, Institutes of Biomedical Sciences, Shanghai Medical College, Fudan University, Shanghai, China.

Background: Male breast cancer (MBC) is a rare malignancy, but its global incidence has shown a notable increase in recent decades. Factors such as limited health literacy, inadequate health education, and reluctance to seek medical attention contribute to the late-stage diagnosis of most MBC patients. Consequently, there is an urgent need for a highly specific and sensitive diagnostic approach to MBC.

View Article and Find Full Text PDF

Background: Adrenocorticotropin (ACTH)-dependent Cushing's syndrome can arise from a pituitary tumour (Cushing's disease) or an ectopic ACTH-secreting tumour, making precise differentiation essential for effective treatment. Bilateral inferior petrosal sinus sampling (BIPSS) is the gold standard for this differentiation, but false-negative results can limit its accuracy. Adding prolactin (PRL) measurement to BIPSS has been proposed to improve diagnostic precision.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!