Purpose: To quantify the abnormal corneal thinning and posterior surface steepening that is observed in keratoconus with an Ectasia Index.
Methods: Optical coherence tomography (OCT) was used to image the corneas of normal individuals and patients with varying stages of keratoconus (manifest, subclinical, and forme fruste). Maps of corneal pachymetry and posterior surface mean curvature were generated, and an Ectasia Index was calculated by multiplying Gaussian fits obtained from the two types of maps. Repeated five-fold cross-validation was used to evaluate the ability of the Ectasia Index to differentiate between normal and keratoconic eyes. The classification performance of the Ectasia Index was compared to minimum pachymetry and maximum posterior mean curvature.
Results: Thirty-two eyes from 16 normal individuals, 89 eyes from 63 patients with manifest keratoconus, 16 eyes from 15 patients with subclinical keratoconus, and 26 eyes from 26 patients with forme fruste keratoconus were included in the study. During cross-validation, 100% of the eyes with manifest (89 of 89) and subclinical (16 of 16) keratoconus were correctly classified by the Ectasia Index. The average classification accuracy for the forme fruste keratoconus group was 63 ± 21% (16.4 of 26). The specificity for the normal group was 91 ± 10% (29.1 of 32). The Ectasia Index had a higher sensitivity for keratoconus detection and similar specificity in comparison to minimum pachymetry and maximum posterior mean curvature.
Conclusions: The Ectasia Index could be a valuable additional metric for clinicians to consider when screening for keratoconus. .
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10311947 | PMC |
http://dx.doi.org/10.3928/1081597X-20220711-01 | DOI Listing |
Ann Surg Oncol
January 2025
Department of Surgery, National Defense Medical College, Tokorozawa, Saitama, Japan.
Background: Tumor size (TS) in pancreatic ductal adenocarcinoma (PDAC) is one of the most important prognostic factors. However, discrepancies between TS on preoperative images (TSi) and pathological specimens (TSp) have been reported. This study aims to evaluate the factors associated with the differences between TSi and TSp.
View Article and Find Full Text PDFInt J Clin Pediatr Dent
December 2024
Department of Orthodontics, Yenepoya Dental College, Yenepoya (Deemed to be University), Mangaluru, Karnataka, India.
Introduction: This study describes a novel device known as "SAVE" to effectively protract the deficient maxilla in class III malocclusion by quantifying and evaluating the changes in the maxilla through a finite element analysis (FEA).
Materials And Methods: The patented novel SAVE device was three-dimensionally modeled using Autodesk Fusion 360. An existing computed tomography (CT) scan of a patient exhibiting class III malocclusion was used to generate a finite element (FE) model.
J Neurophysiol
January 2025
Department of Sports Science, Zhejiang University, Hangzhou, Zhejiang, China.
Human postural control system has the capacity to adapt to balance-challenging perturbations. However, the characteristics and mechanisms of postural adaptation to continuous perturbation under the sensory conflicting environments remain unclear. We aimed to investigate the functional role of oscillatory coupling drive to lower-limb muscles with changes in balance control during postural adaptation under multisensory congruent and incongruent environments.
View Article and Find Full Text PDFBMC Oral Health
January 2025
Center for Plastic & Reconstructive Surgery, Department of Stomatology, Affiliated People's Hospital, Zhejiang Provincial People's Hospital, Hangzhou Medical College, Hangzhou, Zhejiang, China.
Background: The purpose of this study was to evaluate the validity of near-infrared light reflection for detecting different depths of proximal caries in posterior teeth and to compare it with commonly used clinical oral examinations and bitewing radiography images.
Methods: Twenty-six patients with a total of 516 proximal surfaces were included in this study. The ground truth of the proximal caries was determined through a consensus reached by two experienced dentists after an intraoral examination assisted by bitewing radiographs.
Chin J Traumatol
January 2025
Department of Emergency Surgery and Orthopaedic Surgery, Qilu Hospital of Shandong University, Jinan, 250012, China. Electronic address:
Purpose: The fixation method commonly employed worldwide for treating unstable fractures of the posterior pelvic ring is the percutaneous iliosacral screw technique. However, prolonged operation time and frequent fluoroscopies result in surgical risks. This study aimed to investigate whether a new triangulation method could reduce operative and fluoroscopy times and increase the accuracy of screw placement.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!