Background: This in vitro study aims to evaluate the accuracy of dental implant placement by a novel image-guided hybrid robotic system for dental implant surgery (HRS-DIS).

Methods: The HRS-DIS with a 5 degree of freedom (DOF) serial manipulator and a 6 DOF Stewart platform was developed. To evaluate the accuracy of repeated drilling, the holes were prepared twice with a 2.2 mm drill. To evaluate the accuracy of dental implant placement, the entry, exit and angle deviations of dental implants were measured.

Results: Twenty-four holes were prepared twice, and mean (±SD) of diameters were measured as 2.2 ± 0.02 mm. A total of 160 dental implants were placed in 32 phantoms by HRS-DIS. The mean (±SD) of the entry, exit and angle deviation were 0.8 ± 0.54 mm, 0.87 ± 0.54 mm and 1.0 1 ± 0.44°, respectively.

Conclusions: The results of the in vitro study preliminarily validated that the HRS-DIS could provide a high accuracy for dental implant surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcs.2452DOI Listing

Publication Analysis

Top Keywords

dental implant
20
implant placement
12
vitro study
12
evaluate accuracy
12
accuracy dental
12
novel image-guided
8
image-guided hybrid
8
hybrid robotic
8
robotic system
8
system dental
8

Similar Publications

Purpose: Implant stability (IS) is crucial to the success of any implant-based therapy. The present work aimed to determine the relationship between primary and secondary stability and a range of variables.

Material And Methods: This retrospective cohort study included a total of 169 patients, who received 445 dental implants.

View Article and Find Full Text PDF

Purpose: The available scientific evidence on the effectiveness of the surgical treatment of peri-implantitis is limited. The aim of this study was to assess the risk of recurrence or disease progression in patients with peri-implantitis that underwent surgical treatment.

Materials And Methods: A retrospective cohort study was carried out in patients subjected to peri-implant surgery between 2015 and 2021, and with a minimum follow-up of 12 months.

View Article and Find Full Text PDF

Epstein-Barr virus (+) mucocutaneous ulcer (EBVMCU) is an uncommon benign lymphoproliferative lesion that develops in immunocompromised patients. We present a special case of EBVMCU located in the peri-implant mucosa and we review the oral cases published to date. An 88-year-old man with no medical history of interest was attended in the dental clinic due to an ulcerated tumor located in the peri-implant mucosa.

View Article and Find Full Text PDF

Bioceramics for Guided Bone Regeneration: A Multicenter Randomized Controlled Trial.

Clin Implant Dent Relat Res

February 2025

State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China.

Objectives: To compare the clinical effectiveness of a novel bioceramic (BC) with a control xenograft (BO) for guided bone regeneration (GBR) performed simultaneously with implant placement.

Materials And Methods: This clinical study enrolled patients with insufficient bone volume who required GBR during implant placement to increase bone width using either BC or BO. Outcome measures included a dimensional reduction in buccal bone thickness measured by cone beam computed tomography performed immediately post-surgery and at 6 months postoperatively (ΔHBBT), soft tissue healing at 14 days, 1 month, and 6 months postoperatively, and complications rates.

View Article and Find Full Text PDF

Anaerobic Adhesive Effect on the Counter-Torque of Zirconia Implant Abutment Screws: In Vitro Study.

Clin Implant Dent Relat Res

February 2025

Department of Restorative Dentistry, Faculty of Dentistry, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil.

Introduction: Implantology has become a primary solution for tooth loss due to excellent osseointegration and high long-term success rates. However, complications such as abutment screw loosening, especially in implant-supported single crowns, compromise prosthesis longevity. Anaerobic adhesives (AAs) have shown promise in mechanical fields for preventing screw loosening, but their effectiveness in dental implants, particularly zirconia, remains uncertain.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!