Thin foil body-shield resuscitation barrier device to protect from blood: an experimental study.

Sci Rep

Department of Anaesthesiology and Critical Care Medicine, Medical University of Innsbruck, Anichstr. 35, 6020, Innsbruck, Austria.

Published: August 2022

In times of collective concern about pandemics, body-shield resuscitation barrier devices are more and more considered to protect against transmission of different pathogens between rescuers and patients. The objective of this experimental study was to investigate the characteristics of blood drops dispersed on the surface of four different foils suitable for blanketing patients during resuscitation. We analyzed run-off characteristics of blood stains depending on surface properties of polyvinyl chloride, polyethylene, polyethylene terephthalate and aluminum-coated polyethylene terephthalate. Confocal fluorescence microscopy revealed less cellular density and lack of fibrin networks in blood stains on the four foil surfaces than on paper towel. Delayed clotting went along with larger areas of contamination indicating a greater likelihood of coming into contact with potential germs but a smaller chance of contracting an infection. Space blankets as obligatory components of first aid kits are readily available for rescuers and serve as a mechanical barrier between rescuers and patients during resuscitation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9362170PMC
http://dx.doi.org/10.1038/s41598-022-17915-4DOI Listing

Publication Analysis

Top Keywords

body-shield resuscitation
8
resuscitation barrier
8
experimental study
8
rescuers patients
8
characteristics blood
8
patients resuscitation
8
blood stains
8
polyethylene terephthalate
8
thin foil
4
foil body-shield
4

Similar Publications

In times of collective concern about pandemics, body-shield resuscitation barrier devices are more and more considered to protect against transmission of different pathogens between rescuers and patients. The objective of this experimental study was to investigate the characteristics of blood drops dispersed on the surface of four different foils suitable for blanketing patients during resuscitation. We analyzed run-off characteristics of blood stains depending on surface properties of polyvinyl chloride, polyethylene, polyethylene terephthalate and aluminum-coated polyethylene terephthalate.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!