Objectives: To prospectively compare image quality and apparent diffusion coefficient (ADC) quantification for reduced field-of-view (rFOV)- and multi-shot echo-planar imaging (msEPI)-based diffusion weighted imaging (DWI), using single-shot echo-planar-imaging (ssEPI) DWI as the reference.

Methods: Under IRB approval and after informed consent, msEPI, rFOV, and ssEPI DWI acquisitions were prospectively added to clinical prostate MRI exams at 3.0 T. Image distortion was quantitatively evaluated by root-mean-squared displacement (d). Histogram-based quantitative ADC parameters were compared in a sub-set of patients for proven sites of prostate cancer and matched non-cancerous prostate. Three radiologists also independently evaluated the DWI sequences for subjective image quality and distortion/artifact on a 5-point Likert scale.

Results: Twenty-five patients were included (15 with proven sites of cancer). Average d demonstrated a small but statistically significant reduction in distortion for both rFOV and msEPI relative to ssEPI. Quantitative ADC parameters for prostate tumors demonstrated no significant difference across the 3 DWI acquisitions and each acquisition demonstrated a statistically significant decrease in mean ADC for tumor compared to normal prostate. Qualitative reader assessment demonstrated favorable image quality for rFOV and msEPI, more notable for msEPI.

Conclusions: rFOV and msEPI DWI techniques achieved reduction in image distortion, improvement in image quality, and maintained reproducible ADC quantification compared to the standard ssEPI.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9523455PMC
http://dx.doi.org/10.1016/j.mri.2022.08.008DOI Listing

Publication Analysis

Top Keywords

image quality
20
rfov msepi
12
reduced field-of-view
8
prostate cancer
8
adc quantification
8
ssepi dwi
8
dwi acquisitions
8
image distortion
8
quantitative adc
8
adc parameters
8

Similar Publications

Background: Vestibular schwannoma (VS) is a common intracranial tumor that affects patients' quality of life. Reliable imaging techniques for tumor volume assessment are essential for guiding management decisions. The study aimed to compare the ABC/2 method to the gold standard planimetry method for volumetric assessment of VS.

View Article and Find Full Text PDF

Significance: Optimal meibography utilization and interpretation are hindered due to poor lid presentation, blurry images, or image artifacts and the challenges of applying clinical grading scales. These results, using the largest image dataset analyzed to date, demonstrate development of algorithms that provide standardized, real-time inference that addresses all of these limitations.

Purpose: This study aimed to develop and validate an algorithmic pipeline to automate and standardize meibomian gland absence assessment and interpretation.

View Article and Find Full Text PDF

Cardiac MR image reconstruction using cascaded hybrid dual domain deep learning framework.

PLoS One

January 2025

Medical Image Processing Research Group (MIPRG), Dept. of Elect. & Comp. Engineering, COMSATS University Islamabad, Islamabad, Pakistan.

Recovering diagnostic-quality cardiac MR images from highly under-sampled data is a current research focus, particularly in addressing cardiac and respiratory motion. Techniques such as Compressed Sensing (CS) and Parallel Imaging (pMRI) have been proposed to accelerate MRI data acquisition and improve image quality. However, these methods have limitations in high spatial-resolution applications, often resulting in blurring or residual artifacts.

View Article and Find Full Text PDF

Purpose: A relative afferent pupillary defect (RAPD) is a characteristic clinical sign of optic neuritis (ON). Here, we systematically evaluated ultrasound pupillometry (UP) for the detection of an RAPD in patients with ON, including a comparison with infrared video pupillometry (IVP), the gold standard for objective pupillometry.

Materials And Methods: We enrolled 40 patients with acute (n = 9) or past (n = 31) ON (ON+), 31 patients with multiple sclerosis (MS) without prior ON, and 50 healthy controls (HC) in a cross-sectional observational study.

View Article and Find Full Text PDF

Rationale: Solitary fibrous tumors (SFTs) are spindle cell tumors that typically occur in the pleura and peritoneum, but very rarely in the stomach. To our best knowledge, there are only 10 cases reported in English literature. We reported a case of primary stomach SFT and summarized the characteristics of all previous cases, suggesting that pathologists and surgeons should include this disease in the differential diagnosis list of primary mesenchymal tumor of the stomach.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?