Background Unplanned hospitalizations are common in patients with cardiovascular disease. The "Triage Heart Failure Risk Status" (Triage-HFRS) algorithm in patients with cardiac implantable electronic devices uses data from up to 9 device-derived physiological parameters to stratify patients as low/medium/high risk of 30-day heart failure (HF) hospitalization, but its use to predict all-cause hospitalization has not been explored. We examined the association between Triage-HFRS and risk of all-cause, cardiovascular, or HF hospitalization. Methods and Results A prospective observational study of 435 adults (including patients with and without HF) with a Medtronic Triage-HFRS-enabled cardiac implantable electronic device (cardiac resynchronization therapy device, implantable cardioverter-defibrillator, or pacemaker). Cox proportional hazards models explored association between Triage-HFRS and time to hospitalization; a frailty term at the patient level accounted for repeated measures. A total of 274 of 435 patients (63.0%) transmitted ≥1 high HFRS transmission before or during the study period. The remaining 161 patients never transmitted a high HFRS. A total of 153 (32.9%) patients had ≥1 unplanned hospitalization during the study period, totaling 356 nonelective hospitalizations. A high HFRS conferred a 37.3% sensitivity and an 86.2% specificity for 30-day all-cause hospitalization; and for HF hospitalizations, these numbers were 62.5% and 85.6%, respectively. Compared with a low Triage-HFRS, a high HFRS conferred a 4.2 relative risk of 30-day all-cause hospitalization (8.5% versus 2.0%), a 5.0 relative risk of 30-day cardiovascular hospitalization (3.6% versus 0.7%), and a 7.7 relative risk of 30-day HF hospitalization (2.0% versus 0.3%). Conclusions In patients with cardiac implantable electronic devices, remotely monitored Triage-HFRS data discriminated between patients at high and low risk of all-cause hospitalization (cardiovascular or noncardiovascular) in real time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9496305PMC
http://dx.doi.org/10.1161/JAHA.121.024526DOI Listing

Publication Analysis

Top Keywords

cardiac implantable
16
implantable electronic
16
risk 30-day
16
all-cause hospitalization
16
high hfrs
16
relative risk
12
hospitalization
11
patients
9
remotely monitored
8
electronic device
8

Similar Publications

Background: Recent studies revealed an association between small kidney volume and progression of kidney dysfunction in particular settings such as kidney transplantation and transcatheter aortic valve implantation. We hypothesized that kidney volume was associated with the incidence of kidney-related adverse outcomes such as worsening renal function (WRF) in patients with acute heart failure (AHF).

Methods: This study was a single-center retrospective cohort study.

View Article and Find Full Text PDF

Introduction: The role of the sympathetic nervous system in the initiation and continuation of ventricular tachyarrhythmias (VTA) is well established. However, whether CSD reduces implantable cardioverter-defibrillator (ICD) shocks and recurrent VTA is still uncertain.

Methods: A comprehensive literature search was performed at Medline and Embase until March 2023.

View Article and Find Full Text PDF

Background And Aims: Due to the multitude of risk factors outlined in the guidelines, personalised dual antiplatelet therapy (DAPT) guidance after percutaneous coronary intervention (PCI) is complex. A simplified method was created to facilitate the use of risk stratification. We aimed to compare the predictive and prognostic value of the 'Zuidoost Nederland Hart Registratie' (ZON-HR) classification for bleeding risk with the PREdicting bleeding Complications In patients undergoing Stent implantation and subsEquent DAPT (PRECISE-DAPT) score and to determine the effect of ticagrelor monotherapy versus DAPT in patients with or without high bleeding risk (HBR).

View Article and Find Full Text PDF

Objectives: This fourth report aimed to provide insights into patient characteristics, outcomes, and standardized outcome ratios of patients implanted with durable Mechanical Circulatory Support across participating centers in the European Registry for Patients with Mechanical Circulatory Support (EUROMACS) registry.

Methods: All registered patients receiving durable mechanical circulatory support up to August 2024 were included. Expected number of events were predicted using penalized logistic regression.

View Article and Find Full Text PDF

Background: Guideline-recommended strategies to interrupt chronic anticoagulation with warfarin or direct oral anticoagulants (DOAC) during the perioperative period of cardiac implantable electronic device (CIED) surgery differ worldwide. There is uncertainty concerning the benefits and harms of interrupted and uninterrupted anticoagulation in patients undergoing CIED surgery.

Objectives: To assess the benefits and harms of interrupted anticoagulation (IAC) with either warfarin or DOAC in the perioperative period of CIED surgery versus uninterrupted anticoagulation (UAC), with or without heparin bridging, during an equivalent time frame, for CIED surgery.

View Article and Find Full Text PDF