Purpose: Microwave imaging of breast cancer is considered and a new microwave imaging prototype including the imaging algorithm, the antenna array, and the measurement configuration is presented. The prototype aims to project the geometrical features of the anomalies inside the breast to a single-slice image at the coronal plane depending on the complex dielectric permittivity variation among the tissues to aid the diagnosis.
Methods: The imaging prototype uses a solid cylindrical dielectric platform, where a total of 24 optimized Vivaldi antennas are embedded inside to form a uniform circular antenna array. The center of the platform is carved to create a hollow part for placement of the breast and the multistatic, microwave scattering parameters are collected with the antenna array around the hollow center. The dielectric platform further enhances the microwave impedance matching against the breast fat tissue and preserves the vertical polarization during the measurements. In the imaging phase, a computationally efficient inverse electromagnetic scattering method-reverse time migration (RTM)-is considered and adapted in terms of scattering parameters to comply with the actual measurements.
Results: The prototype system is experimentally tested against tissue-mimicking breast phantoms with realistic dielectric permittivity profiles. The reconstructed single-slice images accurately determined the locations and the geometrical extents of the tumor phantoms. These experiments not only verified the microwave imaging prototype but also provided the first experimental results of the imaging algorithm.
Conclusions: The presented prototype system implementing the RTM method is capable of reconstructing single-slice, nonanatomical images, where the hotspots correspond to the geometrical projections of the anomalies inside the breast.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/mp.15917 | DOI Listing |
As an effective approach to overcome the electronic bottlenecks of conventional electrical radars, microwave photonic radars have demonstrated significant superiority in their perception and recognition capabilities. However, trade-offs exist among the reconfigurability, signal time-bandwidth product (TBWP), linearity, and phase coherence of current photonic radars, which ultimately weaken the overall performance. To address these challenges, a photonic transceiver based on electrically assisted synchronized lasers is proposed and demonstrated, which combines high resolution and multi-band reconfigurability.
View Article and Find Full Text PDFBiotechnol Biofuels Bioprod
January 2025
Institute for Pulsed Power and Microwave Technology (IHM), Karlsruhe Institute of Technology (KIT), Eggenstein-Leopoldshafen, Germany.
Background: The gradual extrusion of water-soluble intracellular components (such as proteins) from microalgae after pulsed electric field (PEF) treatment is a well-documented phenomenon. This could be utilized in biorefinery applications with lipid extraction taking place after such an 'incubation' period, i.e.
View Article and Find Full Text PDFJ Colloid Interface Sci
January 2025
The Department of Medical Imaging, Guangzhou Key Laboratory of Molecular Functional Imaging and Artificial Intelligence for Major Brain Diseases, The Affiliated Guangdong Second Provincial General Hospital of Jinan University, Jinan University, Guangzhou 518037 China. Electronic address:
Microwave dynamic therapy (MWDT) destroy tumor cells using reactive oxygen species (ROS), but its effectiveness is limited by low ROS production and intracellular oxygen (O) availability. This study presents a novel strategy using manganese (II) ion (Mn) doped iron (Fe)-based metal-organic framework (Fe MOF) nanoparticles (NPs) to enhance both O generation and ROS production for improved MWDT. Incorporating Mn into Fe MOF narrows the bandgap from 0.
View Article and Find Full Text PDFWorld J Gastrointest Surg
January 2025
Department of Hepatopancreatobiliary Surgery, Chongqing General Hospital, Chongqing 401147, China.
Microwave ablation (MWA) is emerging as a highly effective treatment for colorectal liver metastases (CRLMs). This review explores the advantages of MWA compared to other ablative techniques such as radiofrequency ablation and cryoablation and highlights its clinical efficacy, safety, and technical considerations. MWA offers significant benefits, including higher intratumoral temperatures, larger ablation zones, and reduced susceptibility to the heat-sink effect, which make it particularly suitable for tumors near large blood vessels.
View Article and Find Full Text PDFDalton Trans
January 2025
Center for Research, Innovation, Development, and Applications (CRIDA), Jaiotec Labs (OPC) Private Limited, Amaravati, AP, 522503, India.
The existing demand for the development of innovative multimodal imaging nanomaterial probes for biomedical applications stems from their unique combination of dual response modalities, , photoluminescence (PL) and magnetic resonance imaging (MRI). In this study, for the first time, neodymium (Nd) and dysprosium (Dy) rare earth (RE) metal ions were co-doped into a hydroxyapatite (HAp) crystal lattice using a simple microwave-assisted synthesis technique to incorporate the essential properties of both the lanthanides in HAp. Theoretical as well as experimental studies were performed on novel Nd:Dy:HAp nanoparticles (NPs) to understand their photoluminescence and magnetic behaviour.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!