Background: Coronal alignment after total knee arthroplasty (TKA) would influence the implant survival. Coronal alignment could be measured on short and full-length X-rays. The goal of the current study was to assess the correlation of short and full-length X-rays to accurate prediction of the true Hip-Knee-Ankle alignment after TKA in the Iranian population.
Methods: Lateral distal femoral and medial proximal tibial angles, FTA, HKA, in 180 Iranian patients (243 knees without extra-articular deformities) were measured and compared on short and full-length standing X-rays of primary TKA pre/postoperatively.
Results: The correlation between the preoperative FTA-short and FTA-long, FTA-short and HKA, and FTA-long and HKA values in degrees were fair, good and good (r = 0.64) (r = 0.73), (r = 0.76), respectively. This correlation for postoperative aMPTA and mMPTA (r = 0.73), and FTA-short and HKA (r = 0.76) values were good and significant (P = 0.001). Also, assessing coronal alignment based on short and full-length measurements would result in varying pre/postoperative alignments (varus, neutral and valgus).
Conclusion: Full length X-rays could not be replaced by short knee X-rays to asses true coronal alignment in TKA; considerable portion of our cases were missorted as varus, neutral or valgus based on the FTA versus the HKA. Intraoperative fixed 5° valgus angle cut of distal femur did not result in postoperative favorable neutral alignment in all cases.
Level Of Evidence: IV.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9358910 | PMC |
http://dx.doi.org/10.1186/s13018-022-03246-7 | DOI Listing |
Oper Neurosurg (Hagerstown)
November 2024
Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA.
Background And Objectives: Accurate intraoperative assessment of coronal alignment is critical to achieving favorable clinical outcomes in adult spinal deformity surgery. However, surgical positioning creates challenges in predicting standing coronal alignment. Gravity-based plumblines require an upright posture and are not possible intraoperatively.
View Article and Find Full Text PDFOrthop J Sports Med
January 2025
The Hospital for Special Surgery, New York, New York, USA.
Background: Traditional freehand techniques in high tibial osteotomy (HTO) have been shown to lack precision and accuracy. Patient-specific instrumentation (PSI) and fixation created from cross-sectional imaging have recently been introduced to address this problem.
Purpose/hypothesis: The purpose of the study was to compare traditional freehand techniques versus PSI in a human cadaveric model of HTO.
Am J Sports Med
January 2025
Department of Orthopedics and Traumatology, Hacettepe University Faculty of Medicine, Ankara, Turkey.
Background: A discoid lateral meniscus (DLM) is the most common meniscus variant and is commonly treated with arthroscopic saucerization. There are mixed data regarding long-term results after surgery, especially in terms of radiological parameters.
Purpose/hypothesis: The aim was to evaluate the functional and radiological results of patients who underwent arthroscopic saucerization for a symptomatic DLM.
J Am Acad Orthop Surg
January 2025
From the Children's Mercy Hospital, Kansas City, MO (Shaw), Children's Health Ireland at Temple Street, Dublin, Ireland (O'Sullivan), the Department of Mechanical Engineering, Polytechnique Montreal, Montreal, Quebec, Canada (Wang and Aubin), and the Sainte-Justine University Hospital Center, Montreal, Quebec, Canada (Wang and Aubin).
Thoracolumbar spinal deformities are a pervasive condition affecting the adolescent and adult patient population. These deformities represent three-dimensional alterations in the coronal, sagittal, and transverse planes with implication on the local, regional, and global alignment. With continued studies, the importance of the overall correction on long-term outcomes has been established.
View Article and Find Full Text PDFInt Orthop
January 2025
University of Lille, 42 rue Paul Duez, 59000, Lille, Nord, France.
Purpose: This study reports the relationship between posterior cruciate ligament (PCL) retention vs resection and soft tissue laxity and balance throughout flexion using a robotically controlled ligament tensioner.
Methods: 55 robotic-assisted TKAs (Total knee arthroplasty) were retrospectively reviewe. The robotic ligament tensioner collected laxity data both before and after PCL resection.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!