Background: Coronal alignment after total knee arthroplasty (TKA) would influence the implant survival. Coronal alignment could be measured on short and full-length X-rays. The goal of the current study was to assess the correlation of short and full-length X-rays to accurate prediction of the true Hip-Knee-Ankle alignment after TKA in the Iranian population.

Methods: Lateral distal femoral and medial proximal tibial angles, FTA, HKA, in 180 Iranian patients (243 knees without extra-articular deformities) were measured and compared on short and full-length standing X-rays of primary TKA pre/postoperatively.

Results: The correlation between the preoperative FTA-short and FTA-long, FTA-short and HKA, and FTA-long and HKA values in degrees were fair, good and good (r = 0.64) (r = 0.73), (r = 0.76), respectively. This correlation for postoperative aMPTA and mMPTA (r = 0.73), and FTA-short and HKA (r = 0.76) values were good and significant (P = 0.001). Also, assessing coronal alignment based on short and full-length measurements would result in varying pre/postoperative alignments (varus, neutral and valgus).

Conclusion: Full length X-rays could not be replaced by short knee X-rays to asses true coronal alignment in TKA; considerable portion of our cases were missorted as varus, neutral or valgus based on the FTA versus the HKA. Intraoperative fixed 5° valgus angle cut of distal femur did not result in postoperative favorable neutral alignment in all cases.

Level Of Evidence: IV.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9358910PMC
http://dx.doi.org/10.1186/s13018-022-03246-7DOI Listing

Publication Analysis

Top Keywords

coronal alignment
16
short full-length
16
full-length x-rays
12
correlation short
8
short knee
8
alignment total
8
total knee
8
knee arthroplasty
8
alignment tka
8
fta-short hka
8

Similar Publications

Background And Objectives: Accurate intraoperative assessment of coronal alignment is critical to achieving favorable clinical outcomes in adult spinal deformity surgery. However, surgical positioning creates challenges in predicting standing coronal alignment. Gravity-based plumblines require an upright posture and are not possible intraoperatively.

View Article and Find Full Text PDF

Background: Traditional freehand techniques in high tibial osteotomy (HTO) have been shown to lack precision and accuracy. Patient-specific instrumentation (PSI) and fixation created from cross-sectional imaging have recently been introduced to address this problem.

Purpose/hypothesis: The purpose of the study was to compare traditional freehand techniques versus PSI in a human cadaveric model of HTO.

View Article and Find Full Text PDF

Background: A discoid lateral meniscus (DLM) is the most common meniscus variant and is commonly treated with arthroscopic saucerization. There are mixed data regarding long-term results after surgery, especially in terms of radiological parameters.

Purpose/hypothesis: The aim was to evaluate the functional and radiological results of patients who underwent arthroscopic saucerization for a symptomatic DLM.

View Article and Find Full Text PDF

Biomechanical Principles of Spinal Deformity Correction in the Thoracolumbar Spine.

J Am Acad Orthop Surg

January 2025

From the Children's Mercy Hospital, Kansas City, MO (Shaw), Children's Health Ireland at Temple Street, Dublin, Ireland (O'Sullivan), the Department of Mechanical Engineering, Polytechnique Montreal, Montreal, Quebec, Canada (Wang and Aubin), and the Sainte-Justine University Hospital Center, Montreal, Quebec, Canada (Wang and Aubin).

Thoracolumbar spinal deformities are a pervasive condition affecting the adolescent and adult patient population. These deformities represent three-dimensional alterations in the coronal, sagittal, and transverse planes with implication on the local, regional, and global alignment. With continued studies, the importance of the overall correction on long-term outcomes has been established.

View Article and Find Full Text PDF

Purpose: This study reports the relationship between posterior cruciate ligament (PCL) retention vs resection and soft tissue laxity and balance throughout flexion using a robotically controlled ligament tensioner.

Methods: 55 robotic-assisted TKAs (Total knee arthroplasty) were retrospectively reviewe. The robotic ligament tensioner collected laxity data both before and after PCL resection.

View Article and Find Full Text PDF