A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Pressure-Induced Fibroid Ischemia: First-In-Human Experience with a Novel Device for Laparoscopic Treatment of Symptomatic Uterine Fibroids. | LitMetric

The purpose of this study was to assess the feasibility of use of a novel uterine fibroid treatment device hypothesized to cause fibroid infarction by increasing intra-tumoral pressure. Between August 2019 and January 2020, 21 uterine fibroids were treated in 16 symptomatic pre-menopausal black women. Pelvic magnetic resonance imaging was performed before the procedure, a day after the procedure and at 1, 3, 6, and 12 months. The subjects were also followed for clinical outcomes and quality of life up to 12 months at a single investigational site. At 3 months, the mean reduction in the fibroid volume was 36.3% (P = .002). Incremental reduction in volume peaked at the end of the follow-up, at the 12-month mark (60.4%; P = .008). There were no procedures in which the users failed to perform laparoscopic pressure suturing of fibroids with the pressure-induced fibroid ischemia device. Improvement in the quality of life was evident in the Health-Related Quality of Life total, Energy/Mood, Control, and Sexual Function domains of the Uterine Fibroid Symptom and Quality of Life questionnaire at 3 months post-procedure. Unanticipated risks were not identified. Serious adverse events were not identified. The initial clinical assessment of the pressure-induced fibroid ischemia device supports feasibility of the approach and does not reveal serious safety concerns. Trial is currently being registered retrospectively (This was a feasibility study and therefore registration was not mandatory).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9360636PMC
http://dx.doi.org/10.1007/s43032-022-01033-7DOI Listing

Publication Analysis

Top Keywords

quality life
16
pressure-induced fibroid
12
fibroid ischemia
12
uterine fibroids
8
uterine fibroid
8
ischemia device
8
fibroid
6
ischemia first-in-human
4
first-in-human experience
4
experience novel
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!