Parabens, triclosan (TCS), bisphenols, benzophenones, and phthalates are typical endocrine disruptors (EDs) with short half-lives in the human body. The concentration levels of those EDs in a spot urine sample are frequently used in exposure assessment studies, and the reproducibility of urinary levels of these nonpersistent EDs should be considered. In the present study, we consecutively collected 45-day first morning void (FMV) urine samples, as well as daily questionnaires, in six recruited participants and measured the urinary concentrations of six parabens, TCS, nine bisphenols, five benzophenones, and ten phthalate metabolites by using high-performance liquid chromatography-tandem mass spectrometry. MeP, EtP, PrP, TCS, BPA, BPS, BPF, and most phthalate metabolites were frequently detected (over 62 % of samples). The intraclass correlation coefficients (ICCs) for ED concentrations in FMV urine samples ranged from fair to excellent for MeP (0.683), EtP (0.702), BPA (0.505), BPS (0.908), BPF (0.887), BP-3 (0.712), mMP (0.661), mEP (0.523), mBP (0.500), miBP (0.724), mBzP (0.961) and all metabolites of DEHP (0.867-0.957), whereas they were low for PrP (0.321) and TCS (0.306). After creatinine adjustment, the values of ICCs for most target EDs were increased with mild to significant improvement. The stability of ED concentrations was affected by daily diet (MeP, TCS, BPA, mMP, miBP, mBP and mBzP), food containers (PrP and mECPP), use of personal care products (HMWP metabolites), pharmaceuticals (EtP) and recorded activities (BPS, mEHP, mBzP, mEHHP and mEOHP), as confirmed by a general linear mixed model. Furthermore, extending the FMV sampling period improved the probability of acceptable reproducibility (ICCs > 0.40) of MeP, EtP, BP-3 and mEP concentrations. For BPS, BPF and HMWP metabolite concentrations showed high probabilities (>80 %) of acceptable reproducibility in the last three days, and the increasing sample size slowly improved the ability to discriminate the subjects. The results were exactly the opposite for BPA concentrations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.scitotenv.2022.157873 | DOI Listing |
Anal Bioanal Chem
January 2025
Doping Control Laboratory, Department of Diagnostic Sciences, Ghent University, Block B, Ottergemsesteenweg 460, BE-9000, Ghent, Belgium.
Dried urine spots have recently been proposed as an alternative matrix in the anti-doping field. Drying urine may open the opportunity to limit microbial and thermal degradation of the prohibited substances during transportation to the anti-doping laboratories without the need for refrigeration or freezing. In this study, a multi-targeted initial testing procedure was developed for the determination of 237 prohibited drugs/metabolites from 11 different classes in dried urine spots.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Signal Theory and Communications, Universidad de Valladolid, 47002, Valladolid, Spain.
Sound-based uroflowmetry (SU) offers a non-invasive alternative to traditional uroflowmetry (UF) for evaluating lower urinary tract dysfunctions, enabling home-based testing and reducing the need for clinic visits. This study compares SU and UF in estimating urine flow rate and voided volume in 50 male volunteers (aged 18-60), with UF results from a Minze uroflowmeter as the reference standard. Audio signals recorded during voiding were segmented and machine learning algorithms (gradient boosting, random forest, and support vector machine) estimated flow parameters from three devices: Ultramic384k, Mi A1 smartphone, and Oppo smartwatch.
View Article and Find Full Text PDFJ Nephrol
January 2025
Department of Medicine, Surgery and Neurosciences, Nephrology, Dialysis and Transplantation Unit, University Hospital of Siena, Siena, Italy.
Background: Renal functional reserve (RFR) measures the difference between the stimulated glomerular filtration rate (GFR) and the baseline GFR to detect early signs of renal functional decline. The protein load test (RFR-T) is the gold standard for RFR assessment but is a complicated procedure. Renal intraparenchymal resistance index (RRI) variation test (DRRI-T) is a non-invasive method to measure renal function reserve using ultrasound.
View Article and Find Full Text PDFJ Hazard Mater
December 2024
School of Environmental Science and Engineering, Tianjin University, Tianjin 300072, China. Electronic address:
This study systematically assessed the performance of a newly developed solid-phase extraction (SPE) material, cellulose-supported aminated β-cyclodextrin polymer (amine-β-CDP@Cellulose), in determining 44 xenobiotics, encompassing endocrine-disrupting chemicals (EDCs), pharmaceuticals, and food additives in urine samples. The primary objective of the research was to synthesize a new sorbent, optimize the extraction protocol, and elucidate the underlying adsorption and desorption mechanisms. Following optimization, it was observed that amine-β-CDP@Cellulose achieved recoveries ranging from 80 % to 120 % for 28 of the 44 targeted xenobiotics, with only three compounds showing recoveries below 50 %.
View Article and Find Full Text PDFAlzheimers Dement
December 2024
The Jackson Laboratory, Bar Harbor, ME, USA.
Background: Late-onset Alzheimer's disease (LOAD) is the leading cause of dementia and a major contributor to increased mortality. Recent human datasets have revealed many LOAD genetic risk factors that are correlated with the degree of AD burden. Further, the complexity and heterogeneity of LOAD appears to be promoted by interactions between genetics and environmental factors such as diet, sedentary behavior, and exposure to toxicants, like lead (Pb), cadmium (Cd), and arsenic (As).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!