Underground-produced Ar can be used for underground nuclear explosions (UNE) detection and for groundwater dating. The quantification of the emanation, that is the fraction of activity produced in the rock that escapes to the pore space, is essential for predicting the background activity expected in natural environments. We propose an experiment in which artificial CaCO powder and natural rock particles are irradiated with neutrons in a routinely operated medical cyclotron, whose energy spectrum is experimentally measured. The produced activity was quantified and compared with the emanated activity to determine the emanating fraction. The results showed consistent and reproducible patterns with a dominance of the recoil process at small scales (<2 mm). We observed emanation values ≤1% with a dependency on the grain size and the inner geometry of particles. Soil weathering and the presence of water increased the recoil emanation. The atoms produced that were instantaneously recoiled in the intra- or inter-granular pore space left macroscopic samples by diffusion on timescales of days to weeks (D = 10 - 10 m s). This diffusive transport determines the activity that prevails in the fluid-filled pore space accessible for groundwater or soil gas sampling.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jenvrad.2022.106966 | DOI Listing |
Appl Radiat Isot
June 2023
Australian Nuclear Science and Technology Organisation (ANSTO), New Illawarra Road, Lucas Heights, NSW, 2234, Australia.
In the framework of the EMPIR project traceRadon, stable atmospheres with low-level radon activity concentrations have to be produced for calibrating radon detectors designed to measure outdoor air activity concentrations. The traceable calibration of these detectors at very low activity concentrations is of special interest to the radiation protection, climate observation, and atmospheric research communities. Radiation protection networks (such as the EUropean Radiological Data Exchange Platform (EURDEP)) and atmospheric monitoring networks (such as the Integrated Carbon Observation System (ICOS)) need reliable and accurate radon activity concentration measurements for a variety of reasons, including: the identification of Radon Priority Areas (RPA); improving the sensitivity and reliability of radiological emergency early warning systems (Melintescu et al.
View Article and Find Full Text PDFEnviron Entomol
April 2023
University of Central Florida, College of Medicine, Department of Internal Medicine, FL 32827, USA.
Spatial repellents are emerging as a promising approach to reduce vector-disease burden; however, the evolution of genetically resistant mosquitoes decreases repellent efficacy. The development of flight chambers to investigate spatial repellent application techniques is vital for sustainable mosquito control. We present an air-dilution chamber as a novel bioassay to study mosquito flight behavior responses to chemical gradients of the volatile, pyrethroid transfluthrin (TF).
View Article and Find Full Text PDFJ Environ Radioact
October 2022
Climate and Environmental Physics and Oeschger Center for Climate Change Research, University of Bern, Sidlerstrasse 5, 3012, Bern, Switzerland.
Underground-produced Ar can be used for underground nuclear explosions (UNE) detection and for groundwater dating. The quantification of the emanation, that is the fraction of activity produced in the rock that escapes to the pore space, is essential for predicting the background activity expected in natural environments. We propose an experiment in which artificial CaCO powder and natural rock particles are irradiated with neutrons in a routinely operated medical cyclotron, whose energy spectrum is experimentally measured.
View Article and Find Full Text PDFEnviron Sci Technol
December 2016
Department of Water Resources and Drinking Water, Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland.
We developed a portable mass spectrometric system ("miniRuedi") for quantificaton of the partial pressures of He, Ne (in dry gas), Ar, Kr, N, O, CO, and CH in gaseous and aqueous matrices in environmental systems with an analytical uncertainty of 1-3%. The miniRuedi does not require any purification or other preparation of the sampled gases and therefore allows maintenance-free and autonomous operation. The apparatus is most suitable for on-site gas analysis during field work and at remote locations due to its small size (60 cm × 40 cm × 14 cm), low weight (13 kg), and low power consumption (50 W).
View Article and Find Full Text PDFAppl Radiat Isot
January 2011
Radiation Protection Bureau, Health Canada, 775 Brookfield Road, Ottawa, ON, Canada.
Strontium isotopes, (89)Sr and (90)Sr, and (226)Ra being radiotoxic when ingested, are routinely monitored in milk and drinking water samples collected from different regions in Canada. In order to monitor environmental levels of activity, a novel semi-automated sensitive method has been developed at the Radiation Protection Bureau of Health Canada (Ottawa, Canada). This method allows the separation and quantification of both (89)Sr and (90)Sr and has also been adapted to quantify (226)Ra during the same sample preparation procedure.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!