Maintaining body temperature in pediatric patients is critical, but it is often difficult to use currently accepted core temperature measurement methods. Several studies have validated the use of the SpotOn sensor for measuring core temperature in adults, but studies on pediatric patients are still lacking. The aim of this study was to investigate the accuracy of the SpotOn sensor compared with that of esophageal temperature measurement in pediatric patients intraoperatively. Children aged 1-8 years with American Society of Anesthesiology Physical Condition Classification I or II scheduled to undergo elective ear surgery for at least 30 min under general anesthesia were enrolled. Body core temperature was measured every 15 min after induction till the end of anesthesia with an esophageal probe, axillary probe, and SpotOn sensor. We included 49 patients, providing a total 466 paired measurements. Analysis of Pearson rank correlation between SpotOn and esophageal pairs showed a correlation coefficient (r) of 0.93 (95% confidence interval [CI] 0.92-0.94). Analysis of Pearson rank correlation between esophageal and axillary pairs gave a correlation coefficient (r) of 0.89 (95% CI 0.87-0.91). Between the SpotOn and esophageal groups, Bland-Altman analysis revealed a bias (SD, 95% limits of agreement) of -0.07 (0.17 [-0.41-0.28]). Between the esophageal and axillary groups, Bland-Altman analysis showed a bias (SD, 95% limits of agreement) of 0.45 (0.22 [0-0.89]). In pediatric patients during surgery, the SpotOn sensor showed high correlation and agreement with the esophageal probe, which is a representative core temperature measurement method.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9359523PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0272720PLOS

Publication Analysis

Top Keywords

spoton sensor
20
pediatric patients
16
core temperature
16
temperature measurement
12
temperature
8
body temperature
8
temperature monitoring
8
sensor compared
8
esophageal
8
compared esophageal
8

Similar Publications

Disease biomarkers in tears are crucial for clinical diagnosis and health monitoring. However, the limited volume of tear samples, low concentration of tear biomarkers, and complex tear composition present challenges for precise testing. We introduce a spot-on testing platform of metal-organic framework (MOF)-based surface-enhanced Raman scattering (SERS) capillary column, which is capable of target molecules selective separation and enrichment for tear biomarkers detection.

View Article and Find Full Text PDF

MicroLOCK: Highly stable microgel biosensor using locked nucleic acids as bioreceptors for sensitive and selective detection of let-7a.

Biosens Bioelectron

September 2024

Interdisciplinary Research Centre on Biomaterials (CRIB), Università degli Studi di Napoli "Federico II", Piazzale Tecchio 80, 80125, Naples, Italy; Dipartimento di Ingegneria Chimica del Materiali e della Produzione Industriale (DICMAPI), University "Federico II", Piazzale Tecchio 80, 80125, Naples, Italy; Center for Advanced Biomaterials for Healthcare@CRIB, Istituto Italiano di Tecnologia (IIT), Largo Barsanti e Matteucci 53, 80125, Naples, Italy. Electronic address:

Chemically modified oligonucleotides can solve biosensing issues for the development of capture probes, antisense, CRISPR/Cas, and siRNA, by enhancing their duplex-forming ability, their stability against enzymatic degradation, and their specificity for targets with high sequence similarity as microRNA families. However, the use of modified oligonucleotides such as locked nucleic acids (LNA) for biosensors is still limited by hurdles in design and from performances on the material interface. Here we developed a fluorogenic biosensor for non-coding RNAs, represented by polymeric PEG microgels conjugated with molecular beacons (MB) modified with locked nucleic acids (MicroLOCK).

View Article and Find Full Text PDF

Thermoregulation is important for maintaining homeostasis in the body. It can be easily broken under anesthesia. An appropriate method for measuring core body temperature is needed, especially for elderly patients, because the efficiency of thermoregulation gradually decreases with age.

View Article and Find Full Text PDF

Maintaining body temperature in pediatric patients is critical, but it is often difficult to use currently accepted core temperature measurement methods. Several studies have validated the use of the SpotOn sensor for measuring core temperature in adults, but studies on pediatric patients are still lacking. The aim of this study was to investigate the accuracy of the SpotOn sensor compared with that of esophageal temperature measurement in pediatric patients intraoperatively.

View Article and Find Full Text PDF

Modular fluorescent sensor motifs are needed to design fluorescent sensors for detecting various cellular processes and functional molecules. Here, we took advantage of the versatility of a new sensor motif to design a series of sensors called SPOTon. SPOTon sensors integrate the signal from either opioids, protein-protein interactions, or protease activities to generate persistent green fluorescence.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!