Comparisons of Core Temperature Between a Telemetric Pill and Heart Rate Estimated Core Temperature in Firefighters.

Saf Health Work

Centre for Health, Sport and Rehabilitation Sciences Research, University of Salford, Greater Manchester, UK.

Published: March 2022

Background: Firefighters may experience high environmental temperatures or carry out intensive physical tasks, or both, which leads to increased core body temperature and risk of fatalities. Hence there is a need to remotely and non-invasively monitor core body temperature.

Methods: Estimated (heart rate algorithm) and actual core body temperature (ingested telemetric pill) measures were collected simultaneously for comparison during training exercises on 44 firefighter volunteers.

Results: Prediction of core body temperature varied, with no specific identifiable pattern between the algorithm values and directly measured body core temperatures. Group agreement of Lin's Concordance of 0.74 (95% Upper 0.75, lower CI 0.73), was deemed poor.

Conclusion: From individual agreement data Lin's Concordance was variable (Min 0.11, CI 0.13-0.01; Max 0.83, CI 0.86-0.80), indicating that the heart rate algorithm approach was not suitable for core body temperature monitoring in this population group, especially at the higher more critical core body temperatures seen.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9346945PMC
http://dx.doi.org/10.1016/j.shaw.2021.11.003DOI Listing

Publication Analysis

Top Keywords

core body
24
body temperature
16
heart rate
12
core temperature
8
telemetric pill
8
core
8
rate algorithm
8
lin's concordance
8
body
7
temperature
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!