A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Benzalkonium chloride, a common ophthalmic preservative, compromises rat corneal cold sensitive nerve activity. | LitMetric

Purpose: Corneal nerves comprise the densest sensory network in the body. Dysfunction of the corneal cold sensitive neurons (CSN) is implicated in ophthalmic disorders, including Dry Eye Disease, the most common ocular surface disorder. The preservative Benzalkonium chloride (BAK) and the mydriatic agent Phenylephrine hydrochloride (PHE) are considered to be inactive at the level of the CSNs. The purpose of this study is to test the impacts of continuous exposures to BAK or PHE at their clinically used concentrations on corneal nerve structure and function.

Methods: In vivo extracellular electrophysiology of the rat trigeminal ganglion was used to monitor CSN functional response to stimuli mimicking physiological states and stressors of the cornea. Corneal nerve structure was evaluated by immunostaining.

Results: Among the tested stimuli, cold probe receptive field stimulation and hyperosmolar stress were the most sensitive methods of detecting activity changes. CSN activity was attenuated after 30 min exposure to either PHE or BAK. After an hour-long washout period, BAK-treated neurons failed to recover activity while PHE-treated neurons showed signs of functional recovery. Intraepithelial nerve density was reduced and nerve fragmentation was increased in BAK-treated corneas, while PHE exposure left corneal nerves structurally intact.

Conclusions: Our study suggests that prolonged ocular instillations of BAK or PHE alter CSN activity through two different processes - irreversible neuronal damage in the case of BAK vs. reversible attenuation in the case of PHE.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtos.2022.07.012DOI Listing

Publication Analysis

Top Keywords

benzalkonium chloride
8
corneal cold
8
cold sensitive
8
corneal nerves
8
bak phe
8
corneal nerve
8
nerve structure
8
csn activity
8
corneal
6
phe
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!