A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Time Line of Occlusion for Intracranial Aneurysms Treated with the Pipeline Embolization Device. | LitMetric

Time Line of Occlusion for Intracranial Aneurysms Treated with the Pipeline Embolization Device.

World Neurosurg

Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri, USA; Department of Neurological Surgery, Washington University School of Medicine, St. Louis, Missouri, USA; Department of Neurology, Washington University School of Medicine, St. Louis, Missouri, USA; California Center for Neurointerventional Surgery, San Diego, California, USA.

Published: October 2022

Background: Rates of aneurysm occlusion following treatment with flow-diverting stents have been quantified at predefined time points in clinical trials, but data characterizing the continuous temporal progression of aneurysm occlusion are lacking. This study used real-world variability in timing of angiographic follow-up to characterize the time line of aneurysm occlusion following treatment with the Pipeline embolization device (PED).

Methods: All aneurysms treated with a PED at our institution between 2011 and 2020 were screened. Nonsaccular or ruptured aneurysms were excluded. Aneurysm occlusion status and time since treatment were recorded for each follow-up angiogram. Aneurysm occlusion was characterized using Kaplan-Meier and Cox proportional hazards analysis after censoring at last follow-up or subsequent treatment.

Results: There were 290 aneurysms in 222 patients analyzed. The median time of observed aneurysm occlusion was 7.5 months, and overall rate of aneurysm occlusion was 77.9%. Larger aneurysms demonstrated a longer median time to occlusion and lower rate of aneurysm occlusion (P = 0.029). There were no observed differences in the time line of occlusion for aneurysms treated with a single PED or multiple PEDs (P = 0.889) or without or with adjunctive coiling (P = 0.771).

Conclusions: Aneurysms treated with a PED had a median time to observed occlusion of 7.5 months. Occlusion of larger aneurysms occurred more slowly than occlusion of smaller aneurysms following flow diversion. The number of PEDs deployed or the use of adjunctive coiling did not affect the time line or likelihood of aneurysm occlusion. These findings may guide optimal timing of follow-up after treatment with a PED.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.wneu.2022.07.084DOI Listing

Publication Analysis

Top Keywords

aneurysm occlusion
36
aneurysms treated
16
occlusion
14
time occlusion
12
median time
12
time
9
aneurysms
9
aneurysm
9
pipeline embolization
8
embolization device
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!