A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of Macrotroponin in a Cohort of Community Patients with Elevated Cardiac Troponin. | LitMetric

Background: Macrotroponin is an important cause of discrepancy between current high-sensitivity cardiac troponin (hs-cTn) assays, however, its clinical significance is unclear. This study examined the effects of macrotroponin and repeat testing by different hs-cTnI assays in a cohort of community patients with elevated hs-cTnI.

Methods: The first residual serum specimen from each patient in the community admitted to hospital with elevated hs-cTnI (Siemens hs-cTnI Centaur) was retested after immunoglobulin depletion and by 5 other hs-cTn assays. Low recovery of cTnI (<40%) following immunoglobulin depletion was considered as macrotroponin. A retrospective chart review was performed for these participants. Investigator-adjudicated diagnosis served as the reference standard.

Results: In our cohort of community patients with elevated troponin (n = 188), participants with macrotroponin (n = 99) often had a multifactorial or indeterminate myocardial injury (56% vs 25%) and were less likely to have acute coronary syndrome (9% vs 28%). On repeat testing of cTn on other platforms, better diagnostic performance (c-statistics) for ischemic and non-ischemic cardiac causes was observed on the Beckman Access hs-cTnI (0.74; 95% confidence interval [CI] 0.67-0.81) or the Abbott hs-cTnI Architect (0.75; CI 0.68-0.82) compared to the Siemens hs-cTnI Vista (0.62; CI 0.54-0.70; P < 0.05). This could be attributed to differences in assay reactivity for macrotroponin. Interestingly, better diagnostic performance was observed in patients without macrotroponin. Although a small number of deaths occurred (n = 16), participants with macrotroponin had better overall survival.

Conclusions: In the low-risk setting, the presence of macrotroponin was clinically associated with multifactorial or indeterminate causes of troponin elevation.

Download full-text PDF

Source
http://dx.doi.org/10.1093/clinchem/hvac118DOI Listing

Publication Analysis

Top Keywords

cohort community
8
community patients
8
patients elevated
8
cardiac troponin
8
hs-ctn assays
8
macrotroponin cohort
4
elevated cardiac
4
troponin background
4
background macrotroponin
4
macrotroponin discrepancy
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!