A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Optical sensor using space-domain active fiber cavity ringdown technique. | LitMetric

Optical sensor using space-domain active fiber cavity ringdown technique.

Sci Rep

Hubei Engineering Technology Research Center of Energy Photoelectric Device and System, Hubei University of Technology, Wuhan, 430068, China.

Published: August 2022

A novel active fiber cavity ringdown (FCRD) technique using frequency-shifted interferometry (FSI) is proposed for the first time. Using this scheme, external parameters can be monitored in the space domain by measuring the ringdown distance instead of ringdown time. A bidirectional erbium-doped fiber amplifier (Bi-EDFA) is employed to compensate the inherent cavity loss for achieving higher sensitivity. And two band-pass filters are used to reduce the amplified spontaneous emission (ASE) noise of the Bi-EDFA. Compared with the well-known time-domain active FCRD scheme, our proposed method enables us to avoid using pulsed laser needed in time-domain active FCRD, it uses continuous-wave laser to inject into the fiber cavity and stabilize the optical power in the fiber cavity, which can suppress the baseline drift of ringdown signal caused by the gain fluctuations of the EDFA and thus improve the detecting precision. Moreover, this novel method enables us to use differential detection method for further reducing the ASE noise, and thus eliminating the baseline drift of ringdown signal. A magnetic field sensor was developed as a proof-of-concept demonstration. The experimental results demonstrate that the proposed sensor with a sensitivity of 0.01537 (1/km·Gs) was achieved. This is the highest magnetic field sensitivity compared to the time-domain active FLRD method. Due to the reduced ASE noise, the stability of the proposed sensing system was also greatly improved.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9352676PMC
http://dx.doi.org/10.1038/s41598-022-17565-6DOI Listing

Publication Analysis

Top Keywords

fiber cavity
16
ase noise
12
time-domain active
12
active fiber
8
cavity ringdown
8
active fcrd
8
method enables
8
baseline drift
8
drift ringdown
8
ringdown signal
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!