Background: The performance of self-expandable stents is being increasingly studied by means of finite-element analysis. As for peripheral stents, transcatheter valves and stent-grafts, there are numerous computational studies for setting up a proper model, this information is missing for stent-retrievers used in the procedure of thrombus removal in cerebral arteries. It is well known that the selection of the appropriate finite-element dimensions (topology) and formulations (typology) is a fundamental step to set up accurate and reliable computational simulations. In this context, a thorough verification analysis is here proposed, aimed at investigating how the different element typologies and topologies - available to model a stent-retriever - affect simulation results.
Method: Hexahedral and beam element formulations were analyzed first individually by virtually replicating a crimping test on the device, and then by replicating the thrombectomy procedure aiming at removing a thrombus from a cerebral vessel. In particular, three discretization refinements for each element type and different element formulations including both full and reduced integration were investigated and compared in terms of the resultant radial force of the stent and the stress field generated in the thrombus.
Results: The sensitivity analysis on the element formulation performed with the crimping simulations allowed the identification of the optimal setting for each element family. Both setting lead to similar results in terms of stent performance in the virtual thrombectomy and should be used in future studies simulating the mechanical thrombectomy with stent-retrievers.
Conclusions: The carried out virtual thrombectomy procedures confirmed that the beam element formulation results were sufficiently accurate to model the radial force and the performance of the stent-retriever during the procedure. For different self-expandable stents, hexahedral formulation could be essential in stress analysis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.medengphy.2022.103836 | DOI Listing |
Cureus
December 2024
Department of Orthopaedics and Traumatology, All India Institute of Medical Sciences, Raipur, Raipur, IND.
Knee pain in patients often involves varus deformity and unicompartmental osteoarthritis (OA). High tibial valgus osteotomy (HTO) is increasingly recognized as an effective treatment, as it realigns the knee's mechanical axis towards the healthier lateral compartment, delaying degenerative changes in the medial compartment and reducing the need for joint replacement. This case report discusses two patients with bilateral knee arthritis and varus deformity who underwent medial opening-wedge high tibial osteotomy (MOWHTO) using Dr.
View Article and Find Full Text PDFCureus
November 2024
Cardiothoracic Surgery Unit, Department of Surgery, University of Port Harcourt Teaching Hospital, Port Harcourt, NGA.
Pulmonary embolism is a common cause of morbidity and mortality. Numerous risk factors have been identified that predispose patients to this disease. This study aims to identify these risk factors and the possible outcomes (recovery or mortality) after receiving treatment from any hospital.
View Article and Find Full Text PDFAnn Vasc Dis
December 2024
Digestive & Liver Surgery, Singapore.
Disseminated venous thromboembolism (VTE) occurs commonly in cancer patients, who tend to have contraindications to systemic thrombolysis and require cancer surgery. Such clinical scenarios are often challenging to manage. In this case report, we illustrate an innovative, single procedural approach in such a patient to remove extensive VTE, improve symptoms, prevent hemodynamic decompensation, and allow for a minimal level of anticoagulation such that necessary cancer surgery can proceed safely.
View Article and Find Full Text PDFJ Vasc Access
December 2024
Clinical Department of Medical, Surgical and Health Sciences, University of Trieste, Trieste, Italy.
The fibroblastic sleeve is a structure potentially enveloping any intravascular device. At ultrasound scan, it typically presents as a thin layer of variably echogenic material covering the catheter surface, which usually tends to remain into the vessel after the catheter removal. However, several case reports have documented its migration toward the heart or pulmonary artery after a central venous catheter removal.
View Article and Find Full Text PDFAnn Ital Chir
December 2024
Department of Cardiovascular Surgery, Centro Cardiologico Monzino IRCCS, 20138 Milan, Italy; Department of Biomedical, Surgical, and Dental Sciences, University of Milan, 20122 Milan, Italy.
Aim: Percutaneous vertebroplasty is generally considered a safe procedure, however, cases of cardioembolism and cardiac perforation have been reported.
Case Presentation: A 69-year-old woman was referred to our emergency department after an outpatient echocardiogram revealed a "thrombus-like" formation involving the right heart. Two weeks before she had undergone percutaneous vertebroplasty of the third to fifth lumbar vertebrae due to osteoporotic fractures.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!