Complete region of interest reconstruction by fusing multiview deformable three-dimensional transesophageal echocardiography images.

Med Phys

Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital and Laboratory of Cardiac Imaging and 3D Printing, Li Ka Shing Institute of Health Science, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China.

Published: January 2023

Background: While three-dimensional transesophageal echocardiography (3D TEE) has been increasingly used for assessing cardiac anatomy and function, it still suffers from a limited field of view (FoV) of the ultrasound transducer. Therefore, it is difficult to examine a complete region of interest without moving the transducer. Existing methods extend the FoV of 3D TEE images by mosaicing multiview static images, which requires synchronization between 3D TEE images and electrocardiogram (ECG) signal to avoid deformations in the images and can only get the widened image at a specific phase.

Purpose: This work aims to develop a novel multiview nonrigid registration and fusion method to extend the FoV of 3D TEE images at different cardiac phases, avoiding the bias toward the specifically chosen phase.

Methods: A multiview nonrigid registration and fusion method is proposed to enlarge the FoV of 3D TEE images by fusing dynamic images captured from different viewpoints sequentially. The deformation field for registering images is defined by a collection of affine transformations organized in a graph structure and is estimated by a direct (intensity-based) method. The accuracy of the proposed method is evaluated by comparing it with two B-spline-based methods, two Demons-based methods, and one learning-based method VoxelMorph. Twenty-nine sequences of in vivo 3D TEE images captured from four patients are used for the comparative experiments. Four performance metrics including checkerboard volumes, signed distance, mean absolute distance (MAD), and Dice similarity coefficient (DSC) are used jointly to evaluate the accuracy of the results. Additionally, paired t-tests are performed to examine the significance of the results.

Results: The qualitative results show that the proposed method can align images more accurately and obtain the fused images with higher quality than the other five methods. Additionally, in the evaluation of the segmented left atrium (LA) walls for the pairwise registration and sequential fusion experiments, the proposed method achieves the MAD of (0.07 ± 0.03) mm for pairwise registration and (0.19 ± 0.02) mm for sequential fusion. Paired t-tests indicate that the results obtained from the proposed method are more accurate than those obtained by the state-of-the-art VoxelMorph and the diffeomorphic Demons methods at the significance level of 0.05. In the evaluation of left ventricle (LV) segmentations for the sequential fusion experiments, the proposed method achieves a DSC of (0.88 ± 0.08), which is also significantly better than diffeomorphic Demons at the 0.05 level. The FoVs of the final fused 3D TEE images obtained by our method are enlarged around two times compared with the original images.

Conclusions: Without selecting the static (ECG-gated) images from the same cardiac phase, this work addressed the problem of limited FoV of 3D TEE images in the deformable scenario, obtaining the fused images with high accuracy and good quality. The proposed method could provide an alternative to the conventional fusion methods that are biased toward the specifically chosen phase.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.15910DOI Listing

Publication Analysis

Top Keywords

tee images
28
proposed method
24
images
16
fov tee
16
sequential fusion
12
method
11
complete region
8
region interest
8
three-dimensional transesophageal
8
transesophageal echocardiography
8

Similar Publications

Background: The role of left ventricular global longitudinal strain (LVGLS) in coronary artery bypass grafting (CABG) and outcomes such as low cardiac output syndrome (LCOS) is not well established. The authors investigated the relationship between LVGLS before and after induction of anesthesia, their differences, and their relationship with LCOS and other outcomes.

Methodology: A prospective observational study was conducted in a public/private hospital with 50 adult patients scheduled for on-pump CABG with normal left ventricular ejection fraction (LVEF).

View Article and Find Full Text PDF

Background: Intracardiac echocardiography (ICE) appears to be a potential alternative for percutaneous left atrial appendage occlusion (LAAO) to transesophageal echocardiography (TEE). Thus, a meta-analysis was performed comparing ICE vs. TEE for LAAO guidance.

View Article and Find Full Text PDF

Background: The optimal imaging modality for selecting the device size in patients with atrial fibrillation undergoing one-stop left atrial appendage occlusion (LAAO) with concomitant pulmonary vein isolation (PVi) remains undefined. We compared preprocedural 3-dimensional computed tomography (3D CT) with intra-procedural transesophageal echocardiography (TEE) and left atrial appendage (LAA) angiography in guiding one-stage PVi and LAAO.

Methods: We measured the LAA ostium diameter using an interactive 3D CT system with a central line-based approach and compared these measurements with those from intra-procedural TEE and angiography, and the actual device size.

View Article and Find Full Text PDF

Using transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) to investigate the occurrence and related causes of iatrogenic atrial septal defect (iASD) after catheter ablation combined with left atrial appendage closure (LAAC) for atrial fibrillation (AF) and its impact on the right heart system. We retrospectively analyzed 330 patients that underwent combined procedure of catheter ablation for AF and LAAC at General Hospital of Northern Theater Command from January 2018 to March 2022. These patients were divided into iASD group and non-iASD group according to whether there was persistent iASD shown on TEE at 3 months after procedure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!