Unlabelled: Efficient spread of respiratory viruses requires the virus to maintain infectivity in the environment. Environmental stability of viruses can be influenced by many factors, including temperature and humidity. Our study measured the impact of initial droplet volume (50, 5, and 1 µL) and relative humidity (RH: 40%, 65%, and 85%) on the stability of influenza A virus, bacteriophage, Phi6, a common surrogate for enveloped viruses, and SARS-CoV-2 under a limited set of conditions. Our data suggest that the drying time required for the droplets to reach quasi-equilibrium (i.e. a plateau in mass) varied with RH and initial droplet volume. The macroscale physical characteristics of the droplets at quasi-equilibrium varied with RH but not with initial droplet volume. We observed more rapid virus decay when the droplets were still wet and undergoing evaporation, and slower decay after the droplets had dried. Initial droplet volume had a major effect on virus viability over the first few hours; whereby the decay rate of influenza virus was faster in smaller droplets. In general, influenza virus and SARS-CoV-2 decayed similarly. Overall, this study suggests that virus decay in media is closely correlated with the extent of droplet evaporation, which is controlled by RH. Taken together, these data suggest that decay of different viruses is more similar at higher RH and in smaller droplets and is distinct at lower RH and in larger droplets. Importantly, accurate assessment of transmission risk requires use of physiologically relevant droplet volumes and careful consideration of the use of surrogates.

Funding: National Institute of Allergy and Infectious Diseases, National Institute of Neurological Disorders and Stroke, National Institutes of Health; Department of Health and Human Services; Flu Lab.

Importance: During the COVID-19 pandemic, policy decisions were being driven by virus stability experiments involving SARS-CoV-2 applied to surfaces in large droplets at various humidity conditions. The results of our study indicate that determination of half-lives for emerging pathogens in large droplets likely over-estimates transmission risk for contaminated surfaces, as occurred during the COVID-19 pandemic. Our study implicates the need for the use of physiologically relevant droplet sizes with use of relevant surrogates in addition to what is already known about the importance of physiologically relevant media for risk assessment of future emerging pathogens.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9347275PMC
http://dx.doi.org/10.1101/2022.07.26.501658DOI Listing

Publication Analysis

Top Keywords

initial droplet
16
droplet volume
16
influenza virus
12
physiologically relevant
12
droplets
10
environmental stability
8
enveloped viruses
8
virus
8
varied initial
8
virus decay
8

Similar Publications

The COVID-19 pandemic has resulted in significant changes in our daily lives, including the widespread use of face masks. Face masks have been reported to reduce the transmission of viral infections by droplets; however, improper use and/or treatment of these masks can cause them to be contaminated, thereby reducing their efficacy. Moreover, regular replacement of face masks is essential to maintaining their effectiveness, which can be challenging in resource-limited healthcare settings.

View Article and Find Full Text PDF

Trace measurement of aerosol chemical composition in workplace atmospheres requires the development of high-throughput aerosol collectors that are compact, hand-portable, and can be operated using personal pumps. We describe the design and characterization of a compact, high flow, Turbulent-mixing Condensation Aerosol-in-Liquid Concentrator (TCALC) that allows direct collection of aerosols as liquid suspensions, for off-line chemical, biological, or microscopy analysis. The TCALC unit, measuring approximately 12 × 16 × 18 cm, operates at an aerosol sample flowrate of up to 10 L min, using rapid mixing of a hot flow saturated with water vapor and a cold aerosol sample flow, thereby promoting condensational growth of aerosol particles.

View Article and Find Full Text PDF

To form nonspherical emulsion droplets, the interfacial tension driving droplet sphericity must be overcome. This can be achieved through interfacial particle jamming; however, careful control of particle coverage is required. In this work, we present a scalable novel batch process to form nonspherical particle-stabilized emulsions.

View Article and Find Full Text PDF

In this research, the emulsification method was used to encapsulate in microparticles of whey protein concentrate (WPC) at different levels (1%, 2%, and 4%) and gum Arabic (GA) at three levels (0/5%, 1%, and 1/5%) and a constant level of sunflower oil (5%). The results showed that emulsions with higher quantities of wall materials exhibited better encapsulation efficiency (67%/57%) and preservation ability at different temperatures, different pH, and presence of 1% bile salt. During the storage time, the droplet size of the emulsion increased more than two times (from 2.

View Article and Find Full Text PDF

Liquid-liquid separation in gut immunity.

Front Immunol

December 2024

Department of Gastrointestinal Surgery, Huadu District People's Hospital, Guangzhou, China.

Gut immunity is essential for maintaining intestinal health. Recent studies have identified that intracellular liquid-liquid phase separation (LLPS) may play a significant role in regulating gut immunity, however, the underlying mechanisms remain unclear. LLPS refers to droplet condensates formed through intracellular molecular interactions, which are crucial for the formation of membraneless organelles and biomolecules.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!