Monitoring cardiovascular and respiratory measurements corresponds to the precision livestock farming (PLF) objective to continuously monitor and assess dairy cows' welfare and health. Changes in heart rate, breathing rate, and oxygen saturation (SpO2) are valuable metrics in human and veterinary medicine to assess stress, pain, illness, and detect critical conditions. The common way to measure heart rate is either manually or with a stethoscope. Under research conditions, heart rate is usually measured with a sports watch chest belt. Breathing rate is obtained by counting the cow's flank movements which is a time-consuming and labor-intensive method that requires training and is prone to human error. No devices are available on the market that enable practical and easy pulse oximetry in farm animals. This study presents a wireless nose ring sensor system (NoRS) composed of thermal and photoplothysmography sensors that attach to the nostrils of four Holstein dairy cows. The NoRS's thermocouple measured the cow's nasal cavity air temperature; an optic sensor measured the IR (660 nm) and RED (660 nm) signals reflected from the cow's nasal septum. Breathing was calculated from the thermocouple signal's center frequency with a fast Fourier transformation or the signal peak count (i.e., oscillations). The breathing rate was compared to breathing observed by concurrently counting the flank movements. Heart rate and SpO2 were measured by integrated pulse oximetry and heart rate monitor module (MAX30101 TinyCircuit) assembled on the NoRS circuit. Heart rate was also measured with FFT and by counting the number of peaks from the optic sensor's raw IR and RED signals. These measures were compared to an off-the-shelf hand-held pulse oximeter's heart rate and SpO2 readings during the same time. The comparisons revealed highly significant correlations for the heart rate readings where the strength of the correlation was sensitive to the method. The correlation between breathing rate and the veterinarian's visual observations was low, albeit significant. Thus, inhale-exhale cycle counting constitutes a more precise approach than flank movement counts. The hand-held device's 96% SpO2 is compatible with near-saturation values expected in healthy cows. The mean NoRS SpO2 reading was 3% less. After further piloting under field conditions, the NoRS will require no animal restraining to automatically and continuously record cows' breathing rate, heart rate, and SpO2.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9495501PMC
http://dx.doi.org/10.1093/jas/skac240DOI Listing

Publication Analysis

Top Keywords

heart rate
36
breathing rate
20
rate
14
rate spo2
12
heart
9
nose ring
8
ring sensor
8
sensor system
8
cardiovascular respiratory
8
rate measured
8

Similar Publications

Background: Intermediate-high risk pulmonary embolism (PE) carries a significant risk of hemodynamic deterioration or death. Treatment should balance efficacy in reducing clot burden with the risk of complications, particularly bleeding. Previous studies on high-dose, short-term thrombolysis with alteplase (rtPA) showed a reduced risk of hemodynamic deterioration but no change in mortality and increased bleeding complications.

View Article and Find Full Text PDF

One-year hemodynamic and clinical outcomes in self-expanding valves: Comparison of ACURATE neo2 versus ACURATE neo.

Cardiovasc Revasc Med

December 2024

Department of Cardiology and Catheterization Laboratories, Shonan Kamakura General Hospital, Okamoto 1370-1, Kamakura City, Kanagawa 247-8533, Japan. Electronic address:

Background/purpose: Transcatheter aortic valve replacement (TAVR) with ACURATE neo2 showed better hemodynamic outcomes by mitigating paravalvular leakage (PVL) compared with ACURATE neo, and revealed promising one-year outcomes in single-arm studies. However, studies comparing the hemodynamic and clinical outcomes of the two valves are still scarce. Therefore, this study aimed to compare the one-year hemodynamic and clinical outcomes between the neo2 and neo.

View Article and Find Full Text PDF

Background: Sedentary behaviour (SB) is detrimental to cardiometabolic disease (CMD) risk, which can begin in young adulthood. To devise effective SB-CMD interventions in young adults, it is important to understand which context-specific SB (CS-SB) are most detrimental for CMD risk, the lifestyle behaviours that cluster with CS-SBs and the socioecological predictors of CS-SB.

Methods And Analysis: This longitudinal observational study will recruit 500 college-aged (18-24 years) individuals.

View Article and Find Full Text PDF

High-sensitivity cardiac troponin T and N-terminal b-type natriuretic propeptide are associated with cardiac and all-cause mortality in older adults - A population-based ten-year follow-up study.

Clin Chim Acta

December 2024

Southwest Finland Wellbeing Services County, Turku University Hospital Services, Geriatric Medicine, 20521 Turku, Finland; Faculty of Medicine, Department of Clinical Medicine, Unit of Geriatric Medicine, University of Turku and Turku University Hospital, 20700 Turku, Finland.

Background: Cardiac troponin T (cTnT) and N-terminal B-type natriuretic propeptide (proBNP) are mainly used as biomarkers to diagnose specific conditions of the heart, but they also have predictive ability. Our aim was to study their associations with cardiovascular and all-cause mortality in an older population in non-acute conditions.

Methods: A population-based study with a ten-year follow-up.

View Article and Find Full Text PDF

Although angiotensin 1-7 (Ang 1-7) and its role as a part of the "protective" axis of the renin-angiotensin system are well described in the literature, the mechanisms of its angiotensin II-like pressor and tachycardic effects following its acute central administration are not fully understood. It was the aim of the present study to examine which receptors contribute to the aforementioned cardiovascular effects. Ang 1-7 and antagonists for glutamate, GABA, vasopressin, thromboxane A (TP), α-adrenergic, and P2X purinoceptors or modulators of oxidative stress were injected into the paraventricular nucleus of the hypothalamus (PVN) of urethane-anesthetized male Wistar rats.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!