Metal and its alloys have been predominantly used in fracture fixation for centuries, but new materials such as composites and polymers have begun to see clinical use for fracture fixation during the past couple of decades. Along with the emerging of new materials, tribological issues, especially debris, have become a growing concern for fracture fixation plates. This article for the first time systematically reviews the most recent biomechanical research, with a focus on experimental testing, of those plates within ScienceDirect and PubMed databases. Based on the search criteria, a total of 5449 papers were retrieved, which were then further filtered to exclude nonrelevant, duplicate or non-accessible full article papers. In the end, a total of 83 papers were reviewed. In experimental testing plates, screws and simulated bones or cadaver bones are employed to build a fixation construct in order to test the strength and stability of different plate and screw configurations. The test set-up conditions and conclusions are well documented and summarised here, including fracture gap size, types of bones deployed, as well as the applied load, test speed and test ending criteria. However, research on long term plate usage was very limited. It is also discovered that there is very limited experimental research around the tribological behaviour particularly on the debris' generation, collection and characterisation. In addition, there is no identified standard studying debris of fracture fixation plate. Therefore, the authors suggested the generation of a suite of tribological testing standards on fracture fixation plate and screws in the aim to answer key questions around the debris from fracture fixation plate of new materials or new design and ultimately to provide an insight on how to reduce the risks of debris-related osteolysis, inflammation and aseptic loosening.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9449446 | PMC |
http://dx.doi.org/10.1177/09544119221108540 | DOI Listing |
Eur J Orthop Surg Traumatol
December 2024
University Hospitals Cleveland Medical Center, Cleveland, USA.
Purpose: Olecranon osteotomy has been associated with loss of reduction, nonunion, implant failure, and migration of wires. We aim to evaluate quality of reduction of the osteotomy site as a predictor of olecranon osteotomy nonunion.
Methods: One hundred and twenty-five distal humerus fractures that underwent open reduction internal fixation (ORIF) were reviewed.
Eur J Orthop Surg Traumatol
December 2024
Department of Orthopaedic Surgery, Royal North Shore Hospital, St Leonards, Australia.
Background: Proximal humerus fractures (PHF) are common with approximately 30% requiring surgical intervention. This ranges from open reduction internal fixation (ORIF) to shoulder arthroplasty (including hemiarthroplasty, total shoulder arthroplasty (TSA), reverse total shoulder arthroplasty (RTSA)). The aim of this study was to assess trends in operative interventions for PHF in an Australian population.
View Article and Find Full Text PDFPatient Saf Surg
December 2024
Department of Trauma Surgery, University Hospital Zurich, University of Zurich, Raemistr. 100, Zurich, 8091, Switzerland.
Background: Hemodynamically unstable pelvic ring fractures from high-energy trauma are critical injuries in trauma care, requiring urgent intervention and precise diagnostics. With ongoing advancements in trauma management, treatment strategies have evolved, with some techniques becoming obsolete as new ones emerge. This study aimed to evaluate changes and trends in treatment algorithms for these injuries over approximately 40 years.
View Article and Find Full Text PDFJ Am Acad Orthop Surg
December 2024
From the Zucker School of Medicine at Hofstra/Northwell, New York Hand and Wrist Center of Lenox Hill, New York.
Surgical fixation of unstable distal radius fractures greatly depends on the characteristics of the fracture pattern. Intra-articular fractures of the distal radius often involve several key fragments that require adequate reduction and fixation. The volar lunate facet is just one of those fragments, making up the critical corner of the distal radius articular surface and serving as the keystone to both the radiocarpal and distal radioulnar joints.
View Article and Find Full Text PDFArch Orthop Trauma Surg
December 2024
University Hospital Regensburg, Regensburg, Germany.
Introduction: Patellar fractures are rare at 1% incidence of all fractures. However, they can cause significant functional impairments due to the patella's role in knee joint extension. Current scoring systems lack objectivity in assessing patellar healing.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!