Background: Tilted implants have been recommended as an alternative to the bone graft procedures in implant sites although with possibly higher stress concentrations. This study reviews finite element studies to evaluate patterns of stress and strain in complete-arch prostheses supported by 4‒6 implants.

Methods: A literature search was performed using the online databases. Articles published in English from 2003 to 2015 were reviewed. A total of 100 articles were found related to the subject and after evaluating the titles and abstracts, 18 studies were selected.

Results: By increasing the number of implants, a reduction was detected in the amount of stress in the bone and implants, while in others, the stress level did not change with the increase in the number of implants.

Conclusion: According to finite element analyses, placing a distal implant in an angular position results in better distribution of forces and stresses. Using less cantilever lengths would reduce the stress.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9327566PMC
http://dx.doi.org/10.15171/japid.2018.012DOI Listing

Publication Analysis

Top Keywords

finite element
12
patterns stress
8
stress strain
8
strain complete-arch
8
complete-arch prostheses
8
prostheses supported
8
element analyses
8
stress
5
implants
4
supported implants
4

Similar Publications

Bone tissue regeneration can be affected by various architectonical features of 3D porous scaffold, for example, pore size and shape, strut size, curvature, or porosity. However, the design of additively manufactured structures studied so far was based on uniform geometrical figures and unit cell structures, which often do not resemble the natural architecture of cancellous bone. Therefore, the aim of this study was to investigate the effect of architectonical features of additively manufactured (aka 3D printed) titanium scaffolds designed based on microtomographic scans of fragments of human femurs of individuals of different ages on in vitro response of human bone-derived mesenchymal stem cells (hMSC).

View Article and Find Full Text PDF

In this work, a cost-effective, scalable pneumatic silicone actuator array is introduced, designed to dynamically conform to the user's skin and thereby alleviate localised pressure within a prosthetic socket. The appropriate constitutive models for developing a finite element representation of these actuators are systematically identified, parametrised, and validated. Employing this computational framework, the surface deformation fields induced by 270 variations in soft actuator array design parameters under realistic load conditions are examined, achieving predictive accuracies within 70 µm.

View Article and Find Full Text PDF

Study Design: This study employed a patient-specific finite element model.

Purpose: To quantify the effect of anterior and posterior surgical approaches on adjacent segment biomechanics of the patient-specific spine and spinal cord.

Overview Of Literature: Adjacent segment degeneration (ASD) is a well-documented complication following cervical fusion, typically resulting from accelerated osteoligamentous deterioration and subsequent symptomatic neural compression.

View Article and Find Full Text PDF

Iontronic sensors based on confined space have garnered significant attention due to their promising applications, ranging from single-cell analysis to studies. However, their limited sensitivity has constrained their effectiveness in studying molecular information during physiological and pathological processes. Here, we demonstrate an electrolyte-gated ionic transistor (EGIT) by integrating the confined ion transport behavior in a double-barreled micropipet with an electrolyte-gated transistor configuration, achieving highly sensitive and selective sensing.

View Article and Find Full Text PDF

A Wireless Health Monitoring System Accomplishing Bimodal Decoupling Based on an "IS"-Shaped Multifunctional Conductive Hydrogel.

Small

January 2025

Engineering Research Center of Western Resource Innovation Medicine Green Manufacturing, Ministry of Education, School of Chemical Engineering, Northwest University, Xi'an, 710127, China.

Flexible wearable sensors with bimodal functionality offer substantial value for human health monitoring, as relying on a single indicator is insufficient for capturing comprehensive physiological information. However, bimodal sensors face multiple challenges in practical applications, including mutual interference between various modalities, and integration of excellent mechanical properties, interfacial adhesion, environmental adaptability and biocompatibility. Herein, the multifunctional hydrogel, synthesized through radical grafting and supramolecular self-crosslinking reactions, exhibits excellent thermal sensitivity (TCR = -1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!