Ventilation through a straw.

Anesth Pain Med (Seoul)

Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Korea.

Published: July 2022

Transtracheal jet ventilation can be used for resuscitation of partial airway obstruction. A prerequisite for jet ventilation is that at least a minimum airway opening for gas escape must be secured. Therefore, another option should be considered in cases of complete airway obstruction. The following methods or devices has been used under cricothyrotomy using an intravenous cannula: 1) Ambu (bag valve mask) bagging, 2) Ventrain® , 3) Rapid-O2 oxygen insufflation device (Rapid-O2), and 4) jet ventilation using a dual lumen catheter. During Ambu bagging, extraordinarily high insufflation pressure is required to force oxygen through the cannula. When using a 12-G cannula, long and slow positive-pressure ventilations (10-12 breaths/min) are required, which makes it extremely difficult to compress the bag. Therefore, a 10-G or larger is recommended. Ventrain® is an expiratory assist device capable of forcibly expelling insufflated oxygen through a transtracheal cannula. It is recommended to adjust the inspiratory and expiratory times while observing the chest wall movements. Rapid-O2 is a rescue oxygenation device with adequate ventilation of less importance; therefore, the resulting hypercarbia is inevitable. A 14-G cannula is used. Lastly, jet ventilation using a dual-lumen catheter with a 16-G inflow lumen and 10-G outflow lumen was used to obtain both oxygenation and ventilation. However, the addition of the outer diameters of 16-G and 10-G results in an outer diameter of 5.1 mm, which is too large to puncture the cricothyroid membrane. In conclusion, Ventrain® is considered the most ideal device for use among the devices developed to date.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9346197PMC
http://dx.doi.org/10.17085/apm.22163DOI Listing

Publication Analysis

Top Keywords

jet ventilation
16
airway obstruction
8
ventilation
7
cannula
5
ventilation straw
4
straw transtracheal
4
jet
4
transtracheal jet
4
ventilation resuscitation
4
resuscitation partial
4

Similar Publications

Jet versus vibrating mesh nebulizer for tobramycin aerosol in spontaneously breathing children with tracheostomies - a simulation study.

Anaesth Crit Care Pain Med

December 2024

Perioperative Care Program, Perioperative Medicine Team, Telethon Kids Institute, Northern Entrance, Perth Children's Hospital, 15 Hospital Ave, Nedlands WA 6009, Perth, Australia; Division of Emergency Medicine, Anaesthesia and Pain Medicine, Medical School, The University of Western Australia, 35 Stirling Hwy, Crawley WA 6009, Perth, Australia; School of Human Sciences, The University of Western Australia, 35 Stirling Hwy, Crawley WA 6009, Perth, Australia; Institute for Paediatric Perioperative Excellence, The University of Western Australia, 35 Stirling Hwy, Crawley WA 6009, Perth, Australia; Department of Anaesthesia and Pain Medicine, Perth Children's Hospital, 15 Hospital Ave, Nedlands WA 6009, Perth, Australia. Electronic address:

Article Synopsis
  • Tracheostomy tubes increase the risk of respiratory infections, and initial treatment often involves nebulized tobramycin, but there’s a lack of standardized treatment guidelines.
  • A study used a breathing simulator to test how much tobramycin reaches simulated children with tracheostomies, comparing delivery methods and doses for different child weights.
  • Results showed that jet nebulizers delivered significantly more tobramycin than vibrating mesh nebulizers, highlighting the need for better dosing strategies and further research on drug delivery efficiency and higher dosages for this patient group.
View Article and Find Full Text PDF
Article Synopsis
  • A study tested the effectiveness of inhaled colistin in treating ventilator-associated pneumonia caused by resistant bacteria, using two types of nebulizers: a vibrating mesh nebulizer (VMN) and a jet nebulizer (JN).
  • Patients receiving intravenous (IV) colistin inhalation were randomly assigned to either nebulizer type and compared to a control group receiving IV only over a period of 7 to 10 days, with a focus on clinical improvement.
  • While VMN delivered a higher dose of colistin in lab tests, both nebulizers showed similar clinical outcomes in patients, showing significant benefits over the IV-only group.
View Article and Find Full Text PDF

Introduction: Hypoxemia is a common complication of sedation. This meta-analysis aimed to evaluate the efficacy and safety of supraglottic jet oxygenation and ventilation (SJOV) in preventing hypoxemia during sedative procedures.

Methods: Randomized controlled trials (RCTs) that compared SJOV with conventional oxygen therapy in sedated patients were searched in five databases (MEDLINE, EMBASE, Cochrane Library, China National Knowledge Infrastructure [CNKI], and Google Scholar) from their inception to March 2024.

View Article and Find Full Text PDF

High-frequency jet ventilation in ELBW infants: A review and update.

Semin Fetal Neonatal Med

December 2024

Respiratory Therapy Department, Seattle Children's Hospital, Seattle, WA, USA; Center for Respiratory Biology and Therapeutics, Seattle Children's Research Institute, Seattle, WA, USA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!