Utility of 3D printed models as adjunct in acetabular fracture teaching for Orthopaedic trainees.

BMC Med Educ

Department of Orthopaedics, University Orthopaedics and Hand & Reconstructive Microsurgery Centre, National University Health System, Level 11, Tower Block, 1E Kent Ridge Road, Singapore, 119228, Singapore.

Published: August 2022

Objective: To evaluate the use of 3-D printed models as compared to didactic lectures in the teaching of acetabular fractures for Orthopaedic trainees.

Methods: This was a randomised prospective study conducted in a tertiary hospital setting which consisted of 16 Orthopaedic residents. Ten different cases of acetabular fracture patterns were identified and printed as 3-D models. The baseline knowledge of orthopaedic residents regarding acetabular fracture classification and surgical approach was determined by an x-ray based pre-test. Trainees were then randomly assigned into two groups. Group I received only lectures. Group II were additionally provided with 3-D printed models during the lecture. Participants were then assessed for comprehension and retention of teaching.

Results: Sixteen trainees participated in the trial. Both Group 1 and 2 improved post teaching with a mean score of 2.5 and 1.9 to 4.4 and 6 out of 10 respectively. The post test score for fracture classification and surgical approach were significantly higher for 3-D model group (p < 0.05). Trainees felt that the physical characteristics of the 3-D models were a good representation of acetabular fracture configuration, and should be used routinely for teaching and surgical planning.

Conclusion: 3-D printed model of real clinical cases have significant educational impact compared to lecture-based learning towards improving young trainees' understanding of complex acetabular fractures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9344721PMC
http://dx.doi.org/10.1186/s12909-022-03621-2DOI Listing

Publication Analysis

Top Keywords

printed models
12
acetabular fracture
12
3-d printed
8
orthopaedic residents
8
fracture classification
8
classification surgical
8
surgical approach
8
utility printed
4
models
4
models adjunct
4

Similar Publications

Bone tissue regeneration can be affected by various architectonical features of 3D porous scaffold, for example, pore size and shape, strut size, curvature, or porosity. However, the design of additively manufactured structures studied so far was based on uniform geometrical figures and unit cell structures, which often do not resemble the natural architecture of cancellous bone. Therefore, the aim of this study was to investigate the effect of architectonical features of additively manufactured (aka 3D printed) titanium scaffolds designed based on microtomographic scans of fragments of human femurs of individuals of different ages on in vitro response of human bone-derived mesenchymal stem cells (hMSC).

View Article and Find Full Text PDF

Osteoarthritis, a major global cause of pain and disability, is driven by the irreversible degradation of hyaline cartilage in joints. Cartilage tissue engineering presents a promising therapeutic avenue, but success hinges on replicating the native physiological environment to guide cellular behavior and generate tissue constructs that mimic natural cartilage. Although electrical stimulation has been shown to enhance chondrogenesis and extracellular matrix production in 2D cultures, the mechanisms underlying these effects remain poorly understood, particularly in 3D models.

View Article and Find Full Text PDF

Automated electrochemical oxygen sensing using a 3D-printed microfluidic lab-on-a-chip system.

Lab Chip

January 2025

Nanobioelectronics Laboratory (NBEL), Department of Biomedical Engineering, Ilse Katz Institute for Nanoscale Science and Technology, Ben-Gurion University of the Negev, 8410501 Beer Sheva, Israel.

Dissolved oxygen is crucial for metabolism, growth, and other complex physiological and pathological processes; however, standard physiological models (such as organ-on-chip systems) often use ambient oxygen levels, which do not reflect the lower levels that are typically found . Additionally, the local generation of reactive oxygen species (ROS; a key factor in physiological systems) is often overlooked in biology-mimicking models. Here, we present a microfluidic system that integrates electrochemical dissolved oxygen sensors with lab-on-a-chip technology to monitor the physiological oxygen concentrations and generate hydrogen peroxide (HO; a specific ROS).

View Article and Find Full Text PDF

Transcatheter mitral valve replacement (TMVR) may emerge as a surgical alternative for high-risk patients with severe mitral annular calcification (MAC), yet several questions remain to be addressed. We present the case of a 67-year-old high-risk female patient with severe MAC (MAC score = 8) and mitral stenosis (effective orifice area = 121.3 mm).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?