The study aimed to develop an electrochemical sensor based on glassy carbon, mixed oxide (SiO/TiO/SbO), and carbon black. The material was synthesized, characterized, and used to determine thiamethoxam in raw honey and water. The morphologic structure and electrochemical performance of the sensor was characterized by scanning electron microscopy and cyclic voltammetry. Differential pulse voltammetry with a concentration of 0.1 mol L of Britton-Robinson buffer at pH 7.0 allowed the generation of a method to determine thiamethoxam in a linear range of 0.25 to 100.5 μmol L and with a limit of detection of 0.012 μmol L. The system efficiently quantified traces of thiamethoxam in raw honey and tap water samples. The modified sensor did not present interferences of K, Na, Ca, Mg, glyphosate, imidacloprid, and carbendazim. In addition, the device showed good recovery values for thiamethoxam when applied directly to honey and water samples without any treatment, presenting an electrochemical sensor to monitor real-time hazardous substances in environmental and food matrices.