Drivers have different visual demands across varying contrast and luminance conditions. However, vision assessments for driving are typically conducted under photopic conditions. This study investigated the sensitivity of photopic and mesopic conditions to detect contrast sensitivity (CS) loss in drivers with simulated media opacities. CS was measured in forty-seven healthy drivers aged 18-50 years (mean ± SD: 25.5 ± 6.5) under photopic and mesopic-adapted luminance levels with the Pelli-Robson chart and the Mesotest II (without glare). Media opacities were simulated using white-opacity containing Lee Fog filters (1-5) and CS measured in a randomised order. A significant (p < 0.001) reduction in photopic CS (logCS) was measured with the Pelli-Robson chart only when media opacity was simulated with Fog filter 5 (1.53 ± 0.15, 2.8 triplets reduction) compared to baseline (1.95 ± 0.03). Mean mesopic CS demonstrated a significant (all p < 0.001) reduction from baseline (1.67 ± 0.14) for Fog filters 3 (1.4 triplets, 1.45 ± 0.16), 4 (2.4 triplets, 1.31 ± 0.14) and 5 (4.3 triplets, 1.02 ± 0.15). For Mesotest II, only Fog filter 5 produced a significant reduction (0.10 ± 0.09; p < 0.001) in mean mesopic CS from baseline (0.30 ± 0.01). Mesopic CS is more vulnerable to different levels of simulated media opacity, hence should be considered clinically when assessing visual function in older drivers at risk of media opacity.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9343380 | PMC |
http://dx.doi.org/10.1038/s41598-022-17448-w | DOI Listing |
Retina
January 2025
Department of Ophthalmology, Institute of Clinical Neurosciences of Southern Switzerland (INS), Ospedale Regionale di Lugano, Ente Ospedaliero Cantonale (EOC), Lugano, Switzerland.
Purpose: To assess if drusen volume can serve as structural clinical outcome marker in Malattia Leventinese (ML), and to evaluate whether cones or rods are more affected by its progression, using multimodal imaging and mesopic and two-color scotopic microperimetry.
Methods: This was a prospective monocentric cross-sectional cohort study of participants with genetically confirmed ML. Participants were classified according to morphology.
Invest Ophthalmol Vis Sci
January 2025
UCL Institute of Ophthalmology, University College London, London, United Kingdom.
Purpose: The purpose of this study was to analyze the retinal sensitivity under photopic, mesopic, and scotopic conditions in a cohort of patients affected with KCNV2-associated retinopathy.
Methods: Cross-sectional evaluation of molecularly confirmed individuals was conducted. Data were obtained prospectively.
Am J Ophthalmol
December 2024
Department of Urology (M.E.), Assoc. Prof. M.D., Hitit University Erol Olçok Education and Research Hospital, Çorum, Turkey.
Purpose: To investigate the effect of tamsulosin on iris morphology, ciliary muscle thickness (CMT), pupil diameter (PD), and pupil responses to light using anterior segment optical coherence tomography and corneal topography.
Design: Prospective clinical before-and-after study METHODS: The right eyes of 43 patients with newly diagnosed benign prostatic hyperplasia were included in this study. Iris dilator muscle region (DMR) thickness, sphincter muscle region (SMR) thickness, DMR/SMR ratio, PD (scotopic, mesopic and photopic light conditions), CMT1 (1 mm posterior to the scleral spur), CMT2 (2 mm posterior to the scleral spur), CMT3 (3 mm posterior to the scleral spur) and anterior chamber depth (ACD) were measured before and after dilation.
Am J Ophthalmol
December 2024
Department of Ophthalmology, Emory University School of Medicine (S.S., R.J.L., J.T., N.J.), Atlanta, Georgia, USA. Electronic address:
Purpose: To report the long-term disease course of pentosan polysulfate (PPS) maculopathy following drug cessation.
Design: Single-institution, prospective case series.
Methods: 23 eyes of 12 participants seen at the Emory Eye Center with a diagnosis of PPS maculopathy were included in our study.
Clin Ophthalmol
November 2024
Augenzentrum Erding, Erding, Germany.
Purpose: This study aimed to evaluate one-year clinical outcomes in cataract patients with pre-existing corneal astigmatism implanted with a biconvex aspheric toric monofocal intraocular lens (IOL) with a double C-loop haptic-design.
Methods: One hundred and eighteen patients (236 eyes) with corneal astigmatism (≥0.75D) were implanted bilaterally with the PODEYE toric IOL and assessed up to 1-year after surgery.