Objective: Dedicated multi-pinhole (MPH) collimators have been successfully tested in selected clinical investigations. The aim of our work was to report initial experiences with an MPH collimator set designed for brain perfusion single photon emission tomography (SPECT).
Subjects And Methods: Ten patients underwent sequential technetium-99m-hexamethylpropyleneamineoxime (Tc-HMPAO) SPECT with a dual-head SPECT camera equipped with conventional low-energy parallel hole collimators (LEHR), and with a triple-head system equipped with MPH collimators. Low-energy parallel hole collimators data were reconstructed by filtered back projection (FBP), ordered subset expectation maximization (OSEM), software for tomographic image reconstruction (STIR). In addition, both the parallel hole data and MPH data were reconstructed by Tera-Tomo 3D iterative reconstruction denoted LEHR_TT3D and MPH_TT3D, respectively. Five medical experts visually compared the reconstructed images of the five data sets and defined a ranking sequence from the lowest (1) to the highest (5) image quality. Results were compared using the Friedman test. P values below 0.05 were considered significant.
Results: Low-energy parallel hole collimators acquisition resulted in 5 million, while MPH acquisition in 13 million total counts with 30 and 34 minutes of acquisition time, respectively. Mean rank coefficients of the reconstruction methods were 1.96±0.52, 2.66±0.46, 2.86±0.60, 3.62±0.55, 3.9±0.68 for FBP, STIR, LEHR_TT3D, LEHR_OSEM, MPH_TT3D respectively. The differences between MPH_TT3D-FBP (P<0.01); MPH_TT3D-STIR (P<0.05); LEHR_OSEM-FBP (P<0.01) were significant.
Conclusion: Image quality provided by MPH collimator is comparable to that provided by conventional LEHR imaging. Higher sensitivity has the potential to shorten acquisition time or to reduce the amount of administered activity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1967/s002449912474 | DOI Listing |
Dent Res J (Isfahan)
December 2024
Department of Periodontology, Student Research Committee, Tabriz University of Medical Sciences, Tabriz, Iran.
Background: Chronic apical periodontitis (AP) may influence the outcome of root canal treatment. Thus, it is important to diagnose AP using the best method available. This research was done to compare the diagnostic accuracy of parallel periapical radiography (PR) and different field of views (FOVs) of cone-beam computed tomography (CBCT).
View Article and Find Full Text PDFWorld Neurosurg
January 2025
Bhabha Atomic Research Centre, Mumbai, India-400085.
This paper deals with neuro-registration using tele-manipulation (Master-Slave Manipulation) to facilitate tele-surgery and enhance the overall accuracy and reach of the robot-assisted neurosurgery. Accurate Neuro-registration is important as the success of the surgical procedure highly depends on it. A 6-degree-of-freedom Parallel Kinematic Mechanism (6D-PKM) master-slave robot in tele-manipulation mode is utilized for both neuro-registration and neurosurgery.
View Article and Find Full Text PDFPhys Rev Lett
December 2024
School of Physics and Electronics, Hunan University, Changsha 410082, China.
Electron-hole exchange interaction in two-dimensional transition metal dichalcogenides is extremely strong due to the dimension reduction, which promises valley-superposed excitonic states with linearly polarized optical emissions. However, strong circular polarization reflecting valley-polarized excitonic states is commonly observed in helicity-resolved optical experiments. Here, we present a non-Hermitian theory of valley excitons by incorporating optical pumping and intrinsic decay, which unveils an anomalous valley-polarized excitonic state with elliptically polarized optical emission.
View Article and Find Full Text PDFAppl Radiat Isot
December 2024
Department of Radiological Science, Gachon University, 191, Hambakmoero, Yeonsu-gu, Incheon, Republic of Korea. Electronic address:
The purpose of this study was to propose and evaluate an algorithm that maximizes the image quality of gamma-ray images using a cadmium zinc telluride (CZT) photon-counting semiconductor detector (PCSD) under thin detector thickness conditions. In addition to the CZT PCSD, a pixel-matched parallel-hole collimator that can optimize the spatial resolution of gamma-ray images was modeled. A non-local mean (NLM) noise reduction algorithm was applied to the acquired images using Geant4 Application for Tomographic Emission platform to quantitatively evaluate the overall image quality improvement.
View Article and Find Full Text PDFJ Fish Biol
December 2024
Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration, Woods Hole, Massachusetts, USA.
Ecosystem management requires an integrated understanding of ecological interactions. In the Gulf of Maine (GoM), trophic information pertaining to commercially important groundfishes and nearshore prey communities is lacking. We characterized nearshore communities and groundfish diets using data collected from nearshore surveys (864 bottom trawls and 3638 stomach samples of six groundfish species) conducted biannually (spring and fall) in Midcoast Maine and Penobscot Bay from 2012 to 2022.