A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The influence of narrow aortic bifurcation on limb graft patency: a two-center retrospective study. | LitMetric

Background: Narrow aortic bifurcation (NAB) has been considered as a potential risk factor for graft limb thrombosis after endovascular aortic repair (EVAR). The aim of this study was to compare mid- and long-term outcome of EVAR in patients with NAB and standard aortic bifurcation (SAB).

Methods: Data from patients receiving EVAR were prospectively collected and retrospectively analyzed. In case of angiographic limb stenosis (>50%), additional stenting was performed. Patients with a NAB (≤20mm) were included in the NAB group, the remaining patients in the SAB group. Primary endpoints were limb thrombosis rate and technical success.

Results: A total of 902 patients were included; 18.3% (N.=165/902) in the NAB and 81.7% (N.=737/902) in the SAB group. Mean follow-up time was 43 months (range 0-198 months). Bilateral stenting of the aortic bifurcation was performed in 2.7% (N.=27/902), 8.5% (N.=14/165) in the NAB and 1.4% (N.=10/737) in the SAB group (P=0.001). Limb thrombosis was found in 2.8% (N.=25/902), 3.6% (N.=6/165) in the NAB and 2.6% (N.=19/737) in the SAB group (P=0.55). Technical success was 97.8%, 98.8% in the NAB and 97.6% in the SAB group (P=0.33). Device related reintervention rate was 16% (N.=144/902), 15.2% in the NAB and 16.1% in the SAB group (P=0.75).

Conclusions: Standard EVAR could safely be performed in patients with NAB (≤20mm) when a low threshold for additional stenting was applied. This resulted in no significant higher incidence of limb thrombosis. Additional stent deployment did not increase the complication rate.

Download full-text PDF

Source
http://dx.doi.org/10.23736/S0021-9509.22.12007-0DOI Listing

Publication Analysis

Top Keywords

sab group
24
aortic bifurcation
16
limb thrombosis
16
patients nab
12
nab
10
narrow aortic
8
additional stenting
8
performed patients
8
nab ≤20mm
8
group
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!