The effectiveness of therapeutic ultrasound to the mechanically damaged chondrocyte culture.

Physiother Theory Pract

Department of Microbiology, Institute of Health Sciences, Adnan Menderes University, Aydin, Turkey.

Published: January 2024

Objective: This study aimed to evaluate the efficacy of low intensity (0.1-0.8 Watt/cm) pulsed ultrasound on chondrocyte cell proliferation and migration.

Methods: Low-intensity pulsed ultrasound (frequency 3 MHz, duty cycle 25%, and pulse repetition frequency 150 Hz) for 5 minutes at different spatial average intensities was applied on chondrocyte cells. First, the optimum dose with significantly increased proliferation was determined to be 0.5 W/cm for 5 minutes of duration. Then, 0.5 W/cm ultrasound intensity was applied for durations of 2.5, 5, 7.5, and 10 minutes, and healing was assessed by monitoring cell migration and proliferation.

Results: At the intensity of 0.5 W/cm 48 hours after the application, a statistically significant increase in proliferation (p = .0089) was observed in chondrocyte cells compared to the control group. Proliferation was analyzed at 4, 8, 24, and 48 hours after applying 0.5 W/cm ultrasound for durations of 2.5, 5, 7.5, and 10 minutes. Statistically significant increases were observed at 4 hours (p = .009), 8 hours (p = .032), 24 hours (p = .0084), and 48 hours (p = .00098) with 10 minutes of exposure. For 7.5 min of exposure duration, significant increases were observed at 48 hours (p = .045). In migration for all parameters, no statistically significant improvement (p > .05) was observed.

Conclusion: It was shown that low intensity pulsed ultrasound induces cartilage cell proliferation; therefore, it may have a disease-modifying effect in the treatment of osteoarthritis. However, no positive effect was observed on cartilage cell migration.

Download full-text PDF

Source
http://dx.doi.org/10.1080/09593985.2022.2107466DOI Listing

Publication Analysis

Top Keywords

pulsed ultrasound
12
low intensity
8
cell proliferation
8
chondrocyte cells
8
05 w/cm ultrasound
8
durations 10 minutes
8
cell migration
8
increases observed
8
observed hours
8
cartilage cell
8

Similar Publications

Pulsed Ultrasound-Mediated Drug Delivery Enhancement Through Human Sclera.

Transl Vis Sci Technol

January 2025

Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.

Purpose: The purpose of this study was to characterize whether pulsed ultrasound (PUS) affects transscleral drug delivery.

Methods: Fluorescein sodium (NaF, 376 Da) and fluorescein isothiocyanate-conjugated dextran 40 (FD-40, 40 kDa) were used as model drugs. Human sclera grafts were placed in modified Franz diffusion cells and were treated by PUS (1 megahertz [MHz], 0.

View Article and Find Full Text PDF

Acute Kidney Injury (AKI) is a significant medical condition characterized by the abrupt decline in kidney function.Low-intensity pulsed ultrasound (LIPUS), a non-invasive therapeutic technique employing low-intensity acoustic wave pulses, has shown promise in promoting tissue repair and regeneration. A novel LIPUS system was developed and evaluated in rat AKI models, focusing on its effects on glomerular filtration rate (GFR), blood urea nitrogen (BUN), serum creatinine (SCr), and the Notch1-Akt-eNOS signaling pathway.

View Article and Find Full Text PDF

Background: Treatment of deep carious lesions poses significant challenges in dentistry, as complete lesion removal risks compromising pulp vitality, while selective removal often reduces the longevity of restorations. Herein, we propose a minimally invasive approach using High-Intensity Focused Ultrasound (HIFU) for microscale removal of carious dentine. Concurrently, HIFU's antimicrobial effects against associated cariogenic biofilms and the corresponding thermal and biological impacts on surrounding tissues were investigated.

View Article and Find Full Text PDF

Comparing the long-term effect of extracorporeal shockwave therapy and therapeutic ultrasound in treating trigger finger: A prospective cohort study.

Saudi Med J

January 2025

From the Physiotherapy Department (R. Alfaifi, Juraybi, Alrashed, Alghidani) Al-Rass General Hospital, Al-Rass; from the Neurosurgery Department (H. Alfaifi), Abha Maternity and Child Hospital, Abha, Kingdom of Saudi Arabia.

Objectives: To investigate the long-term effects of Extracorporeal shockwave therapy (ESWT) and ultrasound (US) in treating the trigger finger. Trigger finger, also known as stenosing tenosynovitis, is a common type of tenosynovitis affecting the flexor sheath of any finger. Extracorporeal shockwave therapy and therapeutic US are conservative treatments that use waves of varied frequency to target damaged regions and improve function.

View Article and Find Full Text PDF

Guided wave tomography of pipe bends based on full waveform inversion.

Ultrasonics

January 2025

Department of Civil Engineering and Architecture, Tallinn University of Technology, Ehitajate tee 5, 19086, Tallinn, Estonia. Electronic address:

Pipe bends are recognized as critical areas susceptible to wall thinning, a phenomenon instigated by abrupt changes in the fluid flow direction and velocity. Conventional monitoring techniques for bends typically depend on localized ultrasonic measurements of thickness. While these methods are effective, they can be time-consuming compared to the use of permanently installed transducers, a strategy employed in guided wave tomography (GWT).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!