"Leukerin powder 10%" containing mercaptopurine (6-MP) is an oral anticancer drug that requires careful handling. As a powder formulation, there are risks of exposure due to scattering during dispensing and possible 6-MP contamination to other drugs due to adhesion to the packaging machine. We previously reported that wiping with an alcohol-containing towel is useful for removing scattered powder after dispensing. However, it is recommended to wipe disk-type powder-packaging machines with water instead of cleaning with the alcohol-containing towel. Hence, we scattered 6-MP powder 100 mg (total amount of 6-MP: 10 mg), and then wiped with water three times using different types of cloth each time. We confirmed that third time wiping cloth did not have any 6-MP. Furthermore, we confirmed that the adhering 6-MP could be removed by wipe-cleaning (water-wiping twice and dry-wiping once) after dispensing 6-MP powder at two pharmacies that routinely dispensed 6-MP powder using a disk-type powder-packaging machine. In addition, we confirmed the adhesion of 6-MP in parts of the machine not cleaned by wipe-cleaning and also in parts that were washed only with water, in both the pharmacies. Based on the above observations, we recommend the following steps for cleaning disk-type powder-packaging machines after dispensing 6-MP powder: (1) wipe-cleaning that includes water-wiping twice and then dry-wiping once, (2) cleaning all areas of the packaging machine, and (3) wipe-cleaning with water before washing with water.

Download full-text PDF

Source
http://dx.doi.org/10.1248/yakushi.22-00045DOI Listing

Publication Analysis

Top Keywords

disk-type powder-packaging
16
6-mp powder
16
dispensing 6-mp
12
6-mp
10
powder-packaging machine
8
packaging machine
8
alcohol-containing towel
8
powder-packaging machines
8
water-wiping dry-wiping
8
powder
7

Similar Publications

"Leukerin powder 10%" containing mercaptopurine (6-MP) is an oral anticancer drug that requires careful handling. As a powder formulation, there are risks of exposure due to scattering during dispensing and possible 6-MP contamination to other drugs due to adhesion to the packaging machine. We previously reported that wiping with an alcohol-containing towel is useful for removing scattered powder after dispensing.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!